68 |
3.4
File:CV-TAC400_IN_MAN_NF_REV6.doc
Revised: September 2, 2014
Part No: 40-82B113
Configurations
Basic Master with Slave Unit
These instructions are for a CV-TAC400 configured as a master device to call suites over the telephone and
allow entry through a single door when the correct telephone key is pressed.
Hardware Connections
All hardware connections are to be made before applying power to the unit.
1. Connect the Telephone Line
A dedicated telephone line is required. TIP and RING connections are provided to allow connection to
a telephone line. Typically, TIP is green and RING is red.
Figure 14 - Master CV-TAC400 Tip and Ring Connections
2. Connect the Modem Module (Optional)
A modem module is used to connect to a remote computer for programming the CV-TAC400. The
remote computer must have a modem connection and calls the CV-TAC400. Details of programming
the CV-
TAC400 are contained in the section “Using the SFTD5205 Software”
When a modem connection is used the CV-TAC400 must be configured to use a shared phone line.
The telephone line connected to the modem module may be the same telephone line used by the CV-
TAC400 to call the suites.