DEFROST
CYCLE
ON
CYCLE
POWER
I / O
TEMP
RECALL
TEMP
SETTING
!
REMINDER
ALERT
CLEAN CONDENSER
CNTRL-PNL-AIRSCREEN-C
(F) Temp Recall -
Press to display either
the “Actual Internal
Cabinet” or “Set Point”
Temperature.
(D) Temp Display -
Unit may display either “
Actual Internal Cabinet
” actual temperature, or desired “
Set Point
”
Temperature in either Fahrenheit “dgF” (33°F to 38°F) or Celsius “dgC” (.56°C to 3.33°C) Scale.
Actual: The factory default setting shows the actual internal cabinet temperature and acts as a digital thermometer.
Set Point: To have temperature read-out display the “Set Point” temperature, press and hold the “Temp Recall”
button for five (5) seconds. The display will flash either “S” (Set), or “A” (Actual) to indicate which mode is active.
To switch back again, repeat this step holding the “Temp Recall” button for five (5) seconds.
To momentarily review the alternate display value, press and release the Temp Recall button
(G) DEFROST
Press to initiate “
ON DEMAND DEFROST
”
- OR - Over-ride a defrost cycle in progress
Defrost cycle is automatic.
(A) On/Off Switch -
Serves two functions, turns
cabinet ON or OFF and
also allows you to change
the temperature scale from
Degrees (F) Fahrenheit to
Degrees (C) Celsius
as required.
(B) Power
Indicator Light -
Indicates that
the power is on
(C) Cycling Indicator Light -
Indicates cabinet is cooling down
(H) Clean Condenser Reminder -
Your unit comes with a clean condenser
reminder light, located next to the up and down
arrow temperature control buttons. The most
important thing you can do to insure a long,
reliable service life for your Air Curtain Ultra
is to regularly clean the condenser coil.
The condensing unit requires regularly scheduled
cleaning to keep the finned condenser clean of
lint and dust accumulation. Keeping the condenser
clean allows the unit to operate efficiently,
use less energy and achieve top performance
values. The clean condenser light will illuminate
approximately every 60 days of run time to remind
you its time to care for your unit and
clean the condenser coil. Reset the clean
condenser timer by pressing the clean condenser
button.
Refer to the “
General cleaning and maintenance
”
section of this manual for proper cleaning
instructions.
Every “event” or time the unit is used with the
door open, the coil will build-up ice, reducing the
effectiveness of the overall operation of the unit.
Defrost feature allows proper defrosting of the
accumulated condensation and ice build-up on
the coil. Check water pan for a higher water level
which indicates a successful defrost of the coil.
Certain conditions may require
3 repeated sequential defrosts.
(E) Temperature
Setting -
TO CHANGE
TEMPERATURE:
Press
UP
Arrow - or -
DOWN
Arrow.
Operating temperature
is pre-set at 34°F (1.1°C)
with temperature range
33°F to 38°F
(.56°C to 3.33°C).