Delivery Inspections & Electrical Requirements, Continued
:
Packaging: Your Air Curtain Refrigerator is shipped from the factory on a wood pallet and packaged in a durable cardboard container. The carton
is attached to the wooden skid with the use of large stables. These should first be removed to avoid scratching the unit when lifting off the crate.
Remove the wooden pallet and strapping material, and the unit should be rolled off the skid. Avoid laying the unit on its front, side or back for
removal of the pallet.
Note: Cambro does not recommend laying the unit down on its front, side or back. However, if you must, please be certain to allow the unit to remain
in an upright position afterwards for 48 hours before plugging the unit in or attempting to place the unit in to service, to assure that the compressor
oils and refrigerant may settle.
Cambro’s policy on damaged goods:
There are two types of damaged merchandise: VISIBLE DAMAGE and CONCEALED DAMAGE.
A. CRATE HAS VISIBLE DAMAGE:
1. The product / crate being received is visibly damaged.
2. The receiver should
refuse the damaged merchandise.
3. Receiver should
sign the bill of lading indicating which merchandise is being “refused due to damage”
B. CONCEALED DAMAGE:
1. Merchandise is damaged and could not be externally detected.
2. Your receiving operation should inspect for this type of damage.
3. Save all packing material.
4. Contact Cambro Customer Service at 833-935-1091 and alert them to the situation.
5. Receiver must call the carrier to schedule an inspection of the damaged merchandise within
15 days.
Electrical
1. Check SERIAL PLATE to be sure the unit is installed on the proper NEMA plug 5-20P (on standard unit) electrical supply.
2. WARNING: This unit is provided with a three-pronged grounding plug. Be sure that the unit is plugged into a properly grounded outlet to
avoid the possibility of electrical shock.
Cord & Plug: Your Air Curtain Refrigerator is supplied with a cord & plug attached. It is shipped coiled at the bottom of the cabinet, secured by a
nylon strip. For your safety and protection, all units supplied with a cord and plug include a special three-prong grounding plug on the service cord.
Select only a dedicated electrical outlet with grounding plug for power source. NOTE: Do not under any circumstances, cut or remove the round
grounding prong from the plug, or use an extension cord.
Power Supply: The supply voltage should be checked prior to connection to be certain that proper voltage for the cabinet wiring is available (refer
to the serial tag to determine correct unit voltage). Make connections in accordance with local electrical codes. Use qualified electrician’s
USE OF
A SEPARATE, DEDICATED 20 AMP CIRCUIT IS REQUIRED.
Size wiring to handle indicated load and provide necessary over-current protector in
circuit (see amperage requirements on the unit’s serial tag).
Wiring Diagram: Refer to the wiring diagram for any service work performed on the unit. Should you require service, please contact Cambro
Customer Service and provide the model and serial number of the unit involved.