Before calling for service, please check the following:

If the unit is NOT COOLING down to the proper temperature, check these two common causes:

1. 

T

he evaporator coils needs defrosting. 

Press the “ON DEMAND DEFROST” button on the  control panel. Unit will defrost in 

approximately 20 minutes. Light above defrost button will illuminate when in defrost. The unit will automatically return to normal 
operation after a defrost cycle, having a transition time of two (2) minutes. 

Certain conditions may require 3 repeated sequential 

defrosts. A “HARD DEFROST”: Consult Cambro Customer Service for HARD DEFROST procedures.

2.  Dirt, lint, and/or dust are on the condenser (compressor) coil.

 To clean the condenser, first disconnect electrical power to the cabinet 

and remove the screws on the front and/or rear louver assembly. Removed louvered panel allowing full access to the front facing condenser. 
Vacuum any dirt, lint, and/or dust from the finned condenser coil, the compressor and other cooling system parts. If significant dirty is 
clogging the condenser fins, use brush or compressed air to blow this clear.

 NOTE: Care should be taken not to bend any of the 

condenser fins, as this will reduce performance and compressor life. 

Replace louver assembly and screws which hold it in place.

If the unit is NOT WORKING at all, please check the following:

•  Is the electrical cord plugged in?
•  Is the circuit breaker on and fuse OK?
•  Is the “ON” indicator light illuminated? Press POWER On/Off button to illuminate.

If after checking the above items and the unit is still not operating properly, please contact Cambro for an authorized service agent.

Phone 833-935-1091 

Email: [email protected]

Spare Parts:
Spare or replacement parts may be obtained through a parts supplier or an authorized service agent.

Phone: 833-935-1091

Warranty Registration:
Complete the enclosed warranty card shipped with the unit, Mail to:

Cambro Manufacturing

 

C/O Food Warming Equipment Co., Inc.

 

P.O. Box 1001

 

Crystal Lake, IL 60039-1001

HELPFUL HINTS FOR TOP PERFORMANCE

•  L

OAD CABINET FROM BOTTOM TO TOP

• 

PUSH PANS AND TRAYS ALL THE WAY BACK TO REAR WALL

• 

UNLOAD CABINET FROM TOP TO BOTTOM

• 

DEFROST UNIT DAILY OR AFTER EACH PROLONGED USAGE

• 

REGULARLY CLEAN CONDENSER (COMPRESSOR) COIL

XI - Service Information

Summary of Contents for AIR CURTAIN ULTRA

Page 1: ...OWNER S MANUAL CAMBRO AIR CURTAIN ULTRA This owner s manual applies to all models that begin with the prefix ACU www cambro com...

Page 2: ...nderstand the contents of this manual and operation Delivery Inspection All Cambro Air Curtain Ultra Refrigerators are shipped in containers to prevent damage Upon delivery of your new Air Curtain Ult...

Page 3: ...ert them to the situation 5 Receiver must call the carrier to schedule an inspection of the damaged merchandise within 15 days Electrical 1 Check SERIAL PLATE to be sure the unit is installed on the p...

Page 4: ...ush down to seat The supports can be installed in a horizontal plane of can be mounted in a slightly sloped orientation to cause the product to slide forward on the sheet pans 4 The LED digital temper...

Page 5: ...rovided standard at 4 1 2 spacing Each tray slide can accommodate one 1 18 x26 pan tray Side Grips Rear Handle For easy mobility and maneuvering stainless steel recessed hand grips are provided on the...

Page 6: ...d defrost time interval This will allow you to select defrost time intervals that work best for your operation You can select unit defrost time intervals from every 4 hours to every 12 hours in one ho...

Page 7: ...tes cabinet is cooling down H Clean Condenser Reminder Your unit comes with a clean condenser reminder light located next to the up and down arrow temperature control buttons The most important thing...

Page 8: ...ve unit plugged in with door closed after use A recommendation would be to defrost after use as well to free coil from ice build up formed during use 5 Your unit is equipped with a smart controller Du...

Page 9: ...ng solutions Check for warnings about use on stainless steel products Repeated use of chlorinated solvents may cause a chemical reaction with the stainless steel which will damage the surface and caus...

Page 10: ...the condenser fins use brush or compressed air to blow this clear NOTE Care should be taken not to bend any of the condenser fins as this will reduce performance and compressor life Replace louver ass...

Page 11: ...7 Internal Mechanical Trouble In Compressor Replace Compressor 5 Condensing unit starts and runs but short cycles on overload protector 1 Additional Current Passing Through Overload Protector Check Wi...

Page 12: ...ycling Determine Reason see 6 previous page Correct 5 Relay Being Influenced By Loose Vibrating Mounting Remount Rigidly 6 Incorrect Run Capacitor Replace With Proper Capacitor 11 Suction line frosted...

Page 13: ...XIII Wiring Diagram...

Page 14: ...and FITNESS FOR A PARTICULAR PURPOSE null and void including any responsibility for damage costs and legal actions resulting from use or installation of product s in any Non commercial setting This st...

Page 15: ..._____________________________________________________________________________________ __________________________________________________________________________________________________________________...

Page 16: ...Telephone 714 848 1555 Toll Free 800 854 7631 Customer Service 800 833 3003 Cambro Manufacturing Company 5801 Skylab Road Huntington Beach California 92647 2056 Printed in USA 12 19...

Reviews: