Chapter 6: RFU-C Configurations
Antenna Connection
phn-4026 003v000
Page 6-22
OMT WG Adaptor Installation
1
Connect the flexible waveguides to the OMT ports either directly or using a suitable adaptor as explained in
on page
2
Connect the other end of the flexible waveguide to the RFU-C Radio port.
1+0 Ready for 2+0 Dual Polarization – Direct Mount Installation
If you are installing a 1+0 configuration and you want to be prepared to upgrade to a 2+0 configuration (for double
capacity), a protective “short” can be used to terminate the unused port. Later, when an additional RFU is installed
on the second port, the short should be removed.
The following steps describe the required items and procedures for the installation.
1
Place the Plate in front of the coupler holder.
2
Tighten the plate to the
upgradable port side
with the
M8 screws and washers supplied with the RFU-C
coupler short plate kit using 21.4 NM torque.