Chapter 6: Configuration and alignment
Using the menu options
Page 6-53
Figure 37 Tools > Spectrum Analyzer page
Table 49 Tools > Spectrum Analyzer page attributes
Attribute
Meaning
Spectrum
Analyzer Daemon
Disabled: The Spectrum Analyzer process is not running on the device.
Enabled: The Spectrum Analyzer process is running on the device,
necessary for displaying results in the web management interface.
Range Full Available: The entire operating range of the device will be scanned.
Custom: The device scans only the range defined by Lower Frequency
and Upper Frequency.
Lower / Upper
Frequency
When Range is configured to Custom, indicates the range in MHz for
which the device will scan.
Scanning Click Start to begin scanning, and Stop to terminate scanning.
Tools > eAlign page
Use the eAlign page to aid with link alignment.