15/36
4. Strap and lift the equipment as indicated in the figure below. The minimum capacity of the
lifting device must be 800 kg. Before installing the equipment please take the following into
consideration.
• FEM 2: 381.0 mm (min) - 382.0 mm (max)
• FEM 3: 476.0 mm (min) - 477.5 mm (max)
• FEM 4: 597.0 mm (min)- 598.5 mm (max)
Before lifting the equipment, check the type plate to confirm the weight of the attachment.
Select the appropriate materials according to the weight (slings, cables, hooks, etc.) Check the
stability of the equipment before lifting.
Only use lifting devices with sufficient capacity for the load and secure the equipment
adequelty, so that it can be lifted safely.
5. Place the equipment parallel to the fork carriage of your lifting device.
6. On mounting the positioner it is necessary to insert the stop A positioned on one of the two
upper jaws inside the slot B positioned on the lift truck side.