12.  TROUBLESHOOTING

OFF

 

     WARNING: Turn off the power supply before performing any operations.

 Do not allow the pump or motor to run  when dry even for a short period.

 Strictly follow the user instructions and if necessary contact an authorised service centre.

PROBLEM

PROBABLE CAUSES

POSSIBLE REMEDIES

1)

The motor does 

not start

1a) Unsuitable power supply

1b) Incorrect electrical connections 

1c)  Engine overload protective device cuts 

in.

1d) Blown or defective fuses

1e) Shaft blocked

1f)  If  the  above  causes  have  already 

been    checked,  the  engine  may  be 

malfunctioning

1a)  Check  that  the  mains  frequency    and  voltage  correspond  to  the 

electrical characteristics shown on the indicator plate

1b)  Connect the power supply cable to the terminal board correctly. Check 

that the thermal overload protection is  set correctly (see data on the 

engine indicator plate) and make sure that the fuseboard upline of the 

engine has been properly connected

1c)  Check the power supply  and make sure that the pump shaft is turning 

freely.  Check  that  the  thermal  overload  protection  has  been  set 

correctly (see engine indicator plate)

1d)  Replace the fuses, check the electric power supply and points a) and  c)

1e)  Remove the cause of blockage as indicated in the “Blocked  pump” 

instruction booklet

1f)  Repair    or  replace  the  engine  by  applying  to  an  authorised  service 

centre

2) 

Pump blocked

2a)  Prolonged  periods  of  inactivity  with 

formation of rust inside the pump

2b)  Presence of solid bodies in the pump 

rotor

2c) Bearings siezed

2a)  Rotation  may  be  started  directly  from    the  pump  shaft  or  from  the 

joint (remember to turn off the electricity supply first ) or contact an 

authorised service centre 

2b)  If possible, dismantle the pump casing  and remove any solid foreign 

bodies  inside  the  rotor,    if  necessary  contact  an  authorised  service 

centre 

2c)  If the bearings are damaged replace them or if necessary contact an 

authorised service centre 

3) 

The pump 

functions  

but no water 

comes out 

3a)  Possible infiltration of air from suction 

tube connections, drain plugs or filling 

of  pump  or  from  the  gaskets  of  the 

suction pipe

3b)  Foot valve  blocked  or suction pipe not 

fully immersed in liquid 

3c) Suction filter blocked

3a) Check which part is not  tight and seal  the connection adequately  

3b)  Clean or replace the bottom valve and use a suction pipe suitable for 

the application 

3c) Clean the filter, if necessary, replace it . See point 2a) also.

4) 

Insufficient flow

4a)  Pipes  and  accessories  with  diameter 

too  small  causing  excessive  loss  of 

head 

4b)  Presence of deposits or solid bodies in 

the internal passages of the rotor 

4c) Rotor deteriorated 

4d) Worn rotor and pump case

4e)  Excessive  viscosity  of  the  liquid 

pumped  (if other than water) 

4f) Incorrect direction of rotation 

4g)  Suction  head  excessive  in  relation  to 

the  suction capacity of pump 

4h) Suction pipe too long 

4a) Use pipes and accessories suitable for the specific application 

4b)  Clean  the  rotor  and  install  a  suction  filter  to  prevent  other  foreign 

bodies from entering 

4c) Replace the rotor, if necessary, contact an authorised service centre 

4d) Replace the rotor and the pump casing 

4e) The pump is unsuitable 

4f) Invert the electrical connections on the terminal board  or control panel 

4g)  Try to close the feeder gate partially and/or reduce the difference in 

level of the pump and the liquid being aspirated 

4h)  Bring the pump closer to the suction tank so as to use a shorter pipe. 

If necessary use a pipe of a wider diameter 

5) 

Noise and 

vibrations 

from the pump

5a) Rotating part unbalanced 

5b) Worn bearings 

5c) Pump and pipes not firmly attached 

5d)  Flow too strong for the diameter of the 

delivery pipe 

5e) Functioning in cavitation 

5f) Unbalanced power supply 

5g) Incorrect alignment of pump-motor unit

5a) Check that no solid bodies are obstructing the rotor 

5b) Replace the bearings 

5c) Anchor the delivery and suction piping as needed 

5d) Use bigger diameters or reduce the pump flow

5e)  Reduce the flow by adjusting the feeder gate  and/or using pipes with 

a bigger internal diameter. See point 4g) too

5f) Check that the mains voltage is right

5g) If necessary, the unit must be re-aligned

6)  

Leakage from 

the mechanical 

seal

6a)  The  mechanical  seal  has  functioned 

when dry or has stuck 

6b)  Mechanical  seal  scored  by  presence 

of abrasive parts in the liquid pumped 

6c)  Mechanical  seal  unsuitable    for  the 

type of application 

6d)  Slight initial drip during filling  or on first 

start-up

In  cases  6a),  6b)  and  6c),  replace  the  seal,  if  necessary  contact  an 

authorised service centre 

6a)  Make sure that the pump casing  (and the suction pipe if the pump is 

not  self-priming) are full of liquid and that all the air has been expelled. 

See point 5 e) too. 

6b)  Install a suction filter  and use a seal suited to the characteristics of the 

liquid being pumped. 

6c) Choose a seal with characteristics suitable for the specific application 

6d)  Wait  for  the  seal  to  adjust  to  the  rotation  of  the  shaft.  If  the  problem 

persists, see points 6a), 6b) or 6c) or contact an authorised service centre.

MXA MXP MGP Rev4.indd   13

13/07/17   17:03

Summary of Contents for MGP

Page 1: ... κλειστού τύπου αντλίες åÓÌÓ ÎÓ Ì Â Ó ËÁÓÌÚ Î Ì Â ÏÌÓ ÓÒÚÛÔÂÌ Ú Â Ì ÒÓÒ 卧式多级直联泵 MXP MGP MXA ISTRUZIONI ORIGINALI PER L USO Pagina 2 Italiano OPERATING INSTRUCTIONS Page 8 English BETRIEBSANLEITUNG Seite 14 Deutsch INSTRUCTIONS POUR L UTILISATION Page 20 Français INSTRUCCIONES DE USO Página 26 Español DRIFT INSTALLATIONSANVISNINGAR Sidan 32 Svenska BEDIENINGSVOORSCHRIFT Pagina 38 Nederlands ΟΔΗΓΙΕΣ...

Page 2: ...s a risk that the machine could damage or compromise personnel safety The failure to observe electrical information and warnings could damage the machine or compromise personnel safety i Notes and warnings for the correct management of the machine and its parts Operations that could be performed by the final user After carefully reading of the instructions is responsible for maintenance under norm...

Page 3: ...taly MONTORSO XXXXXXX Q min max X X m3 h XXXXXXX H max min X X m IP XX n XXXX min 220 380Y V3 50Hz cosø X X X A XXXXXXXX S1 l cl X X kg X kW XHp S F VICENZA 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 3 TECHNICAL FEATURES 3 1 Technical data Dimensions and weight see technical catalogue Nominal speed 2900 3450 rpm Protection IP54 Supply voltage Frequency up to 240V 1 50 60 Hz up to 480V 3 50 60 Hz Check...

Page 4: ...ps so that they do not transmit stress strain or vibrations to the pump par 13 fig 3 Tighten the pipes or union coupling to the extent sufficient to ensure a tight seal par 13 fig 6 Excessive torque may cause damage to the pump When the pipe or union coupling is mounted keep the pump casing connection blocked with a second wrench making sure the connection is not deformed by excessive tightening T...

Page 5: ...ump before opening the gate valve To avoid any risk of danger to users and the creation of harmful thermal stress in the pump and system due to large temperature differentials wait until the water has cooled inside the pump before starting again If the water is overheated on account of prolonged operation with a non primed or insufficiently filled pump suction lift operation wait until cool before...

Page 6: ...e is a risk of freezing par 13 fig 5 Before restarting the unit check that the shaft is not jammed and fill the pump casing completely with liquid 8 2 Dismantling the system Close the suction and delivery gate valves and drain the pump casing before dismantling the pump 8 3 Dismantling the pump OFF Close the suction and delivery gate valves and drain the pump casing before dismantling the pump par...

Page 7: ...See point 2a also 4 Insufficient flow 4a Pipes and accessories with diameter too small causing excessive loss of head 4b Presence of deposits or solid bodies in the internal passages of the rotor 4c Rotor deteriorated 4d Worn rotor and pump case 4e Excessive viscosity of the liquid pumped if other than water 4f Incorrect direction of rotation 4g Suction head excessive in relation to the suction ca...

Page 8: ... 标准维护工作 必须由有资格的专业电工才能进行的操作 专业电工 有资格的专业电工 负责所有电气 设备的运行包括维护 应具有高压电资格 必须由有专业技术资格的人才能进行的操作 专业技术人员 正常状态下 具有产品安装和 维护能力的专业技术人员 可以从事电气和机 械方面的维护工作 能够从事简单的与设备维 护相关的电气和机械方面的操作 指示必须使用个别的保护装置 OFF 必须关断电源并断开与电源的连接才能进行的 操作 ON 必须接通电源才能进行的操作 1 2 制造商名称和地址 制造商名称 CALPEDA S P A 地址 Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italia www calpeda it 1 3 授权操作者 本产品只能由有经验的终端用户和专业技术人员操作 i 禁止终端用户操作那些只能由专业技术人员操 作的工作 ...

Page 9: ...专业技术人员必须认真遵从所有的适 用标准和法律 包括产品应用地当地的规章 产品安装使用应符合现行的安全法规 不当的使用可能会对人身 动物和其他对象造成损害 制造商对由于不当使用或未按本操作手册和标牌的标 示使用所造成的损坏不负责任 i 按照日程维护计划表操作并及时更换损坏的部 件可使产品工作在最佳状态 使用CALPEDA S P A或其指定代理商提供的原 厂配件 不要撕下或改变产品上的标识 当产品有问题或部件有损坏的情况下不要启动 产品 由于维修时会全部或部分的拆开产品 因此之前 务必断开供电电源 4 2 安全装置 本产品具有全外部壳体 可防止与内部部件的任何接触 4 3 剩余风险 当按照本产品的设计功能和所有安全规则使用本产品 时没有剩余风险 4 4 通告和安全预示 没有任何安全预示在此类产品上面 4 5 个别的保护装置 在安装 使用和维修期间 建议操作人员使用适合此 操作的个别保护装置...

Page 10: ...7 2 首次启动 OFF 请注意 千万不要使泵干态运行 一定先注水后再启动泵 当泵位置高于水面 吸上扬程为负章13 图3 时 或者正压 头太小 小于1m 不足以打开止回阀 应通过自吸孔注水 章13 图 4 当泵位置低于水面 吸上水头为正 章13 图 1 慢慢打 开吸入端闸阀 直到完全打开 以此对泵注水 这时 应确保出水端的闸阀处于打开状态以排除空气 启动前 应手工检查轴的自由度 方法是 在电机侧用螺丝刀旋转轴端即可 对于三相电机 要检查旋转方向是否如泵盖上的箭头 方向所示 否则 切断电源 并改变其中两相的联接 确认泵工作在其性能参数范围内 实际的工作电流不 能超过铭牌上标注的电流值 否则应调整出口阀门开 度或压力开关的设置 如果吸不上水 不出水 或者压力表显示压力波动 应检查并确保所有的入口管路连接气密性完好并保证 泵壳上的加 排水堵密封完好 永远不要让泵闭阀运行超过5分钟 泵中的水长期的...

Page 11: ...体 章13 图 5 在再次启动泵 电机机组前 一定检查轴是否被卡住 并往泵内注水 8 2 系统的分解 分解前 关闭进出口隔栅 8 3 泵的拆解 OFF 关闭进出口闸阀 拆卸水泵前排空水泵 图5 拆卸及回装详见构造图中的剖面图 9 处理 OFF 产品的最终处理应由专业公司操作 确保专业公司是按照材料分类方式处理 按照当地的法规和有关环境保护的国际准则处理 10 备件 10 1 订购备件 订购备件时请根据剖面图提供备件的名称和位置编号 及泵铭牌上的数据 型号 参数和序列号 备件需求请电话 传真 邮件给CALPEDA S P A 11 部件名称 名称 14 00 泵壳 14 04 带垫片的注水堵 14 06 O形圈 14 12 带垫片的放水堵 14 16 O形圈 14 20 O型圈 14 24 螺丝 16 00 入口壳体 16 14 柱塞阀 15 15 弹簧 16 16 O型圈 16 17 单流...

Page 12: ...到位并正确连接 3b 清洁或更换底阀并使用适合于工况的进口管路 3c 清洁过滤器 或更换 同时参见2a 4 流量不足 4a 管路及其附件直径过小导致水 头损失过大 4b 流道内有沉积物或固体异物 4c 转子腐蚀损坏 4d 转子和泵壳磨损 4e 泵送介质粘度过高 不同于 水 4f 旋转方向错误 4g 吸程超过了泵的自吸能力 4h 入口管路过长 4a 请使用符合工况的管路及其附件 4b 清洁转子并安装入口过滤器以防止外部固体异物进入 4c 更换转子 如果需要请联系授权服务中心 4d 更换转子和泵壳 4e 泵不适用 4f 在控制柜内或电机接线盒内对调任意两根接线 4g 请尝试部分关闭供水阀门和 或降低泵的安装高度 液 体将被吸入 4h 使泵尽量靠近入口水箱以便缩短进口管路 如有必要应 选用大口径进水管 5 泵 的 噪 音 和 震动 5a 转子不平衡 5b 轴承磨损 5c 泵和管路未固定到位 5d...

Page 13: ...ico Draining Entleerung Vidange Vaciado Avtappning Aftappen Αποστράγγιση ëÎË 排空 Fig 2 Funzionamento in aspirazione Suction lift operation Saugbetrieb Fonctionnement en aspiration Funcionamiento en aspiración Sugande funktion Zuigsituatie Θέση λειτουργίας με κάθετη αναρρόφηση ê ÓÚ Â Û Ó Ìfl ÊË ÍÓÒÚË 负吸水头工作 Regolatore automatico Automatic regulator Schaltautomat Regulateur automatique Regulador autom...

Page 14: ...N 25 Øi 28 mm G 1 1 4 DN 32 Øi 36 mm MXA 205 405 Hs Hs MXA 205 203 2 0 4 404 4 0 5 403 404 204 100 200 450 600 203 100 200 450 600 Hs m 2 4 6 8 405 100 450 600 600 500 500 600 600 h mm 205 500 500 500 600 403 100 450 600 600 1 2 3 4 5 6 7 8 m 20 10 25 15 5 ft t min 0 5 1 2 3 4 Valvola di non ritorno Check valve Rückschlagventil Clapet de non retour Válvula de retención Backventil Terugslagklep Βαλ...

Page 15: ...3 25 01 28 00 25 10 64 15 25 11 25 11 25 11 25 10 64 15 28 08 MXP 403 MXP 403 60 MXP 202 MXP 402 MXP 202 60 MXP 402 60 MXP 201 60 MXP 401 60 MXP 203 60 MXP 402 60 64 15 25 10 MXP 403 60 2 MXP 205 MXP 405 MGP 205 MGP 405 3 MXP 405 MGP 405 MXP 404 MXP 201 60 MXP 202 60 MXP 401 60 82 04 14 04 MGP 404 MGP 405 MGP 403 MGP 203 14 00 14 12 MGP 402 MGP 202 14 24 70 00 Tab 1 TAB 1IEC 60335 1 Corrente nomin...

Page 16: ...M MXP MXPM MGP MGPM pomptype en serienummer zoals vermeld op de typeplaat aan de EG voorschriften 2006 42 EU 2009 125 EU 2014 30 EU 2014 35 EU voldoen Verordening van de commissie nr 640 2009 SF VAKUUTUS Me CALPEDA S p A vakuutamme että pumppumme MXA MXAM MXP MXPM MGP MGPM malli ja valmistusnumero tyyppikilvcstä ovat valmistettu 2006 42 EU 2009 125 EU 2014 30 EU 2014 35 EU direktiivien mukaisesti ...

Reviews: