25 / EN
•
Generally, for different wall types, especially walls with bricks, perforated blocks,
or blocks with limited firmness, this mounting must be checked for safety. The wall
mounting screws must be able to support three times the weight of the heater
full of water.
•
Do not place objects under the water heater, to avoid damages.
Before connecting the heater, you must:
•
Check that the product characteristics comply with the requirements for its correct
operation. See the Electrical Specifications Table.
*For commercial use, we recommend 3 phases
Cable most be 100% copper.
ELECTRICAL SPECIFICATIONS TABLE
Modelo
Eleva 15 kW
Tipo
Electric Instantaneous Water Heater
Power (W)
15000
Supply voltage (VAC)
220
Phase
2*
Amperage (A)
68
Recommended breaker (A)
3 x 30 A (Double pole)
Required cable diameter
3 x 10 AWG
This heater must be installed according to the following indications regarding the
presence of:
•
Humidity:
do not install the appliance in humid environments.
•
Ice:
do not install the appliance in environments with a probability of temperatures
dropping to critical levels with a risk of ice formation.
•
Sun rays:
do not expose the appliance directly to solar rays, not even through
glass.
•
Dust/vapors/gases:
do not install the appliance in notably aggressive
environments, such as those with acid vapors, dusts, or saturated gas.
•
Electric shock:
do not install the appliance directly on electrical lines that are not
protected from voltage fluctuations.