PAD Configuration commands
^IDNT
PAD identification string
This command is used to configure an identification string to be sent at the
beginning of each PAD session.
This string will be sent followed by a terminating <LF> either as the first UDP
datagram or the first bytes of a TCP stream.
If this parameter is not set (empty) no identification data is sent, nor is the
terminating <LF>
Default:
<empty>
Storage:
&W
Command values:
^IDNT=<ID>
Where <ID> is a string with maximum length of 32 bytes.
^ICTO
Inter-character timer
This command is used to configure the Inter-Character timeout used by the PAD
service when assembling packets for transmission.
The PAD will send a packet of data every time the buffer is full (512 Bytes) or if the
serial data line is idle for longer than the time specified by this command.
Default:
50
Storage:
&W
Command values:
^PADM=<timeout> Where <timeout> is a number between 0 and 65535
milliseconds.
CDM800 Series V.250 Manual
Page 23 of 33
To suit software version 1.52.2
4/4/2008