Procedure to terminate the subscriber cables
Route subscriber cable over the pegs
Step
Action
1.
Terminate the sheath ground to the main ground bar.
2.
On the factory installed subscriber cable, remove the cover from one cable
binder.
3.
On the outside plant cable, remove the opposite cover from the matching
cable binder.
4.
Use the appropriate tool to squeeze the two connectors together for a tight
fit.
5.
Repeat steps 2 through 4 for all binders in the outside plant cable.
After the subscriber cable is installed and sealed, route the
cable over the cable management pegs along with the factory
installed equipment cables.