User Manual
2253i / 2253iX
AMETEK
California Instruments
39
3.6.2 Output Terminal Block - OUTPUT
Each chassis has a single AC output terminal strip. The output terminal strip must be covered using
the supplied AC Output safety cover. The terminal strip is large enough to accommodate required wire
gauge sizes. The terminal strip is located in the lower left corner on the rear panel of the unit. (Looking
from the back). Connector type is Magnum, A307104R50.
The AC output terminal strip accommodates a #6 ring or spade lug. The use of sleeved ring lugs
(12/10-6 Yellow sleeve lug) or compressed cable lug for the load carrying output wiring is
recommended.
Following output terminal lugs and connectors are included in i/iX ship kit:
Use
CI P/N
Description
Qty supplied
For use with:
OUTPUT (TB1)
FS2004
Ring Lug 12/10-6
4
A, B, C, N
SENSE (TB2)
410636
Mating Connector
1
Sense A, B, C, N
Connector
TB1
Terminal
Output
1
Output øA
2
Output øB
3
Output øC
4
Output Neutral (Common)
Table 3-1: Output Terminal connections.