User Manual
2253i / 2253iX
AMETEK
California Instruments
13
2. Specifications
Specifications shown are valid over an ambient temperature range of 25
±
5
°
C and apply after a 30
minute warm-up time. Unless otherwise noted, all specifications are per phase for sine wave output
into a resistive load. For three phase configurations or mode of operation, all specifications are for Line
to Neutral (L-N) and phase angle specifications are valid under balanced load conditions only.
Specifications for 2253i models are identical to those for the 2253iX except where noted.
2.1 Electrical
2.1.1 Input
Parameter
Specification
Line Voltage:
(single phase, 2 wire +
ground (PE))
115 to 230 VAC ± 10 %
Line VA:
2940 VA / 2850 W
Line Current at nominal
input voltage:
< 20 Arms @ 115V and 1500 VA output
(Note: Max. AC input current limited to 20 Arms.
Breaker may trip above 1500 VA output power)
< 15 Arms @ 230V and 2250 VA output
Line Current at low line
input voltage, full power:
< 20 Arms @ 103.5V (Derated output power)
< 17 Arms @ 207V (Full output power)
Line Frequency:
47-63 Hz
Efficiency:
77 % (typical @ full load)
Power Factor:
0.98 (typical @ full load)
Inrush Current:
< 160 Apk for less than 2 ms at 230V + 10% AC input
< 80 Apk for less than 2 ms at 115V + 10% AC input
Hold-Up Time:
> 10 ms
Isolation Voltage:
1350 VAC input to output
1350 VAC input to chassis