16. Error Messages
Any errors that occur during operation from either the front panel or the remote control interface will
result in error messages. Error messages are displayed on the LCD display. They are also stored in
the error message queue from which they can be queried using the SYST:ERR? Query. The error
queue has a finite depth. If more error messages are generated than can be held in the queue, a
queue overflow message (Error –400, “Queue Overflow) will be put in the last queue location. To
empty the queue, use the system error query until a 0, “No Error” result is received.
Errors appearing on the LCD will generally remain visible until the user moves to another screen. If
multiple error messages are generated in succession, only the last message will be visible as there is
only space for one error message on the LCD display.
The same area of the display is also used to display status messages.
The table below displays a list of possible error and status messages along with their possible cause
and remedy.
Number Message String
Cause
Remedy
0
"No error"
No errors in queue
-100
"Command error"
Unable to complete
requested operation
Unit may be in a mode inconsistent with
request.
-102
"Syntax error"
Command syntax
incorrect.
Misspelled or unsupported command
-103
"Invalid separator"
SCPI separator not
recognized
See SCPI section of programming
manual.
-104
"Data type error"
Data type invalid.
Check command for supported data
types
-108
"Parameter not allowed"
One or more additional
parameters were
received.
Check programming manual for correct
number of parameters
-109
"Missing parameter"
Too few parameters
received for requested
operation
Check programming manual for correct
number of parameters
-110
"Command header error"
Command header
incorrect
Check syntax of command.
-111
"Header separator error"
Invalid command
separator used.
Use semi-colon to separate command
headers
-112
"Program mnemonic too
long"
Syntax error
Check programming manual for correct
command syntax
-113
"Undefined header"
Command not recognized
error
Check programming manual for correct
command syntax
-120
"Numeric data error"
Data received is not a
number
Check programming manual for correct
command syntax
-121
"Invalid character in
number"
Number received contains
non-numeric character(s)
Check programming manual for correct
command syntax
-123
"Exponent too large"
Exponent in number
exceeds limits
Check programming manual for correct
parameter range
-128
"Numeric data not
allowed"
Number received when
number is not allowed.
Check programming manual for correct
command syntax
-168
"Block data not allowed"
Block data was sent.
Check programming manual for correct
command syntax
-200
"Execution error"
Command could not be
Command may be inconsistent with