MIsCellaneOus serVICe InFOrMaTIOn

The control and high limit thermostats are equipped with electronic sensors that are connected to the spa’s plumbing. Never cut, or kink the wires that connect the 

sensors to the thermostats within the control box.
The jet pump is equipped with a thermal overload cutoff switch that is designed to protect the pump from overheating. If the pump shuts itself off in an older spa, it could 

indicate failure of the pump motor bearings. If the pump shuts itself off in a new spa, it is usually the result of one or a combination of the following factors:

High Temperature: All Caldera

• 

®

 spa models are equipped with a jet pump shroud that vents the heat generated by the pump motor to the outside of the 

equipment compartment. If the vent is blocked by masonry, grass, or debris, overheating of the jet pump may occur. Once the pump motor has cooled 

sufficiently and any blockage has been removed from the vent opening, the jet pump can be restarted.
Improper Wiring: If the spa is connected with an extension cord, and/or the house wiring is undersized, the pump may starve for voltage and therefore may 

• 

draw more amperage and generate excessive heat.
If the pump is shutting down due to excessive heat, make sure the equipment compartment has adequate ventilation. The air gap at the bottom must not be 

• 

blocked. If your jet pump continues to shut off after short periods of use, contact a qualified service technician.

aCTs InValIDaTInG warranTY

The limited warranty is void if the Caldera spa has been improperly installed, subjected to alteration, misuse, or abuse, or if any repairs on the spa are attempted by 

anyone other than an authorized representative of Watkins Manufacturing Corporation. Alteration shall include any component or plumbing change, electrical conversion, 

or the addition of any non-approved sanitation or water purification device or heating system which contributes to component or unit failure or unsafe operating system. 

Misuse and abuse shall include any operation of the spa other than in accordance with Watkins Manufacturing Corporation printed instructions, or use of the spa in an 

application for which it is not designed; specifically: use of the spa in a non-residential application; damage caused by operation* of the spa at water temperatures outside 

the range of 35°F and 120 °F; damage caused by a dirty, clogged or calcified filter cartridge; damage to the spa surface caused by the use of tri-chloro chlorine, BCDMH, 

misuse of chemical tablets in a floater, acid, or any other spa chemicals or spa surface cleaners which are not recommended by Watkins Manufacturing Corporation; 

damage caused by allowing undissolved spa sanitizing chemicals to lie on the spa surface (no spa surface material can withstand this kind of abuse); damage to 

components or spa surface caused by improper water chemistry maintenance; and damage to the spa surface caused by leaving the spa uncovered while empty of 

water and in direct exposure to sunlight (this may cause solar heating distress in warm weather regions). These are considered abuses and may invalidate this warranty.
*Operation of the spa does not mean “use” of the spa. Watkins Manufacturing Corporation does not recommend using the spa if the water temperature is above or below 

the spa’s control panel temperature range.

DIsClaIMers

Watkins Manufacturing Corporation shall not be liable for loss of use of the Caldera spa, or other incidental, consequential, special, indirect, or punitive costs, expenses 

or damages, which may include but are not limited to the removal of a permanent deck or other custom fixture, or the necessity for crane removal. Any implied warranty 

shall have a duration equal to the duration of the applicable limited warranty stated above. Some states do not allow limitations on how long an implied warranty lasts. 

Under no circumstances shall Watkins Manufacturing Corporation or any of its representatives be held liable for injury to any person or damage to any property, however 

arising.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations may not apply to you.

waTkIns CusTOMer serVICe

If you have any questions about any aspect of your Caldera spa set-up, operation,or maintenance that have not been answered by this manual, consult your Caldera 

dealer.
Watkins Manufacturing Corporation can be reached at: 800-669-1881 (Extension 8432), Monday through Friday, 8 am to 5-pm Pacific Standard Time (PST), or e-mail 

[email protected]

SERVICE

35

Summary of Contents for paradise series

Page 1: ......

Page 2: ...HONE ___________________________________________ SPA MODEL SERIAL NUMBER ____________________________ COVER SERIAL NUMBER ________________________________ In most cities and counties permits will be r...

Page 3: ...rol Option Wireless System Only 20 EQUIPMENT COMPARTMENT Jet Pump Side 21 Controls Side 22 MAINTENANCE Filter Maintenance 23 Filter Cartridge Removal and Cleaning Instructions 23 Diverter Valve Mainte...

Page 4: ...ructions per electrical configuration 230 volt permanently installed models A ground terminal is provided on the terminal block located inside the control box To reduce the risk of electric shock conn...

Page 5: ...spa some medication may cause a user to become drowsy while other medication may affect heart rate blood pressure and circulation Persons taking medications which induce drowsiness such as tranquilize...

Page 6: ...ide Opening of the control box by the spa owner will void the warranty If you have an operational problem carefully go through the steps outlined in the Troubleshooting section If you are not able to...

Page 7: ...gularly to ensure proper levels of sanitizers pH and other water care requirements Drain clean and refill your spa with fresh water on a regular schedule and in accordance with this owner s manual Cle...

Page 8: ...lve 1 Temperature Sensor 2 Euro Directional Jet 3 VersaSsage 4 Jet AdaptaFlo 5 Jet Euphoria 6 Jet Diverter Valve 7 Drain 8 Ozone Jet Heater 9 return Control Panel 10 Pillow 11 Filter Compartment 12 Ac...

Page 9: ...ew Air Control Valve 1 Euro Directional Jet 2 Temperature Sensor 3 AdaptaSsage 4 Jet AdaptaFlo 5 Jet VersaSsage 6 Jet Diverter Valve 7 Drain 8 Speaker Optional 9 Ozone Jet 10 Control Panel 11 Heater r...

Page 10: ...3 4 13 2 14 OVERHEAD VIEW Air Control 1 Euro Directional Jet 2 Euro Pulse 3 Jet VersaSsage 4 Jet Diverter Valve 5 Drain 6 Speaker Optional 7 Ozone Jet Heater 8 Return Control Panel 9 Pillow 10 Filter...

Page 11: ...to TB 1 terminal 6 5 Connect the 10 AWG WHITE wire from the subpanel 30 amp breaker terminal N load neutral to TB 1 terminal 7 6 Connect the 10 AWG GREEN wire from the subpanel GROUND bar to TB 1 syst...

Page 12: ...m WARNING THE EXACT PHYSICAL LOCATION OF THE TERMINALS ON THE GFCI BREAKER WILL VARY BETWEEN MANUFACTURERS CONNECTING THE HOT WIRE TO THE NEUTRAL TERMINAL WILL CAUSE IRREVERSIBLE DAMAGE TO THE CONTROL...

Page 13: ...ter and the equipment compartment door is secured power must be applied to the spa Activate power to the subpanel from the main house panel first Open the door of the electrical subpanel and reset the...

Page 14: ...the face of the VersaSsage AdaptaSsage and AdaptaFlo jets to close the ones that are not in use TIP Turn both pumps on and place the diverter valves to the Mid Position then experiment with each of t...

Page 15: ...be adjusted to provide either a stationary direct stream or by positioning the nozzle to one side or the other a rotating jet stream The VersaSsage jets allow you to regulate the force of the massage...

Page 16: ...Jet System 2 4 Euro Directional jets in footwell Located in LumbarSsage Seat back right 5 Euro Directional jets 2 VersaSsage jets Located in front right seat 2 AdaptaFlo jets 1 VersaSsage jet Combinat...

Page 17: ...aFlo jet Jet Pump 2 Jet System 1 Located in UltraMassage lounge front 6 Sole Soothers 3 VersaSsage jets 2 Euro Directional jets Waterfall Combination Jet System Jet Pump 2 diverter in mid position act...

Page 18: ...csta Seat 8 Euro Directional jets 2 Euro Pulse jets Jet Pump Jet System 1 Located in UltraMassagelounge 6 Sole Soothers 3 VersaSsage jets 2 Euro Directional jets Located in LumbarSsage seat 4 Euro Dir...

Page 19: ...up and used the last temperature value set by the user will be stored in memory If power is disconnected from the spa it will automatically revert to the last set temperature when power is reapplied T...

Page 20: ...music on however when the system mode is deactivated the wireless music system will turn off To activate the system mode perform the following functions Press the MODE button until SYSTM is displayed...

Page 21: ...e the SPA LOCK feature When the Spa Lock is activated the buttons for the JETS LIGHTS temperature control and any other features your spa may have are deactivated To deactivate the Spa Lock press the...

Page 22: ...display AUDIO 1 Press the ON button to display PWR 2 Press the MODE to display VOL 3 Press the MODE to display SETUP 4 Press the ON button to display EQ 5 Press the ON button for EQ Press OFF button f...

Page 23: ...Pump 2 Salina Martinique only 2 Ozone Injector Included with the Optional Monarch 3 CD Ozone Generator kit Unions 4 Temperature Sensor 5 Pump Drain Plug 6 5 2 3 6 1 4b Discharge 4a Suction JET PUMP S...

Page 24: ...22 EQUIPMENT COMPARTMENT 1 2 3 4 Advent 1 Control Box System EnergyPro 2 Circulation Pump EnergyPro 3 Heater Monarch 4 CD Ozone Generator optional CONTROLS SIDE...

Page 25: ...o turn it is likely that sand or grit has become lodged inside the valve body It is very important that this debris is removed as soon as possible to avoid damage to the valve To clean the valves foll...

Page 26: ...Winterizing your spa If you leave the spa unused for a long period of time in severely cold weather you should drain the spa and winterize it to avoid accidental freezing due to a power or equipment...

Page 27: ...e spa pillows 1 Carefully lift one end of the pillow away from the spa shell 2 Continue lifting one end until all pillow retainers are released from the pillow IMPORTANT Just pulling the pillow straig...

Page 28: ...n Do not let the vinyl dry with a soap film on it before it can be rinsed clean Scrub the cover s perimeter and side flaps Rinse clean with water 4 Rinse off the underside of the cover with water only...

Page 29: ...mprove water clarity Ozone Ozone is a powerful oxidizing agent which is produced in nature and artificially by man Ozone forms no by products of chloramines ozone actually oxidizes chloramines and wil...

Page 30: ...aser liquid stain and scale inhibitor and liquid de foamer must always be added directly into or in front of the filter compartment while a jet pump is running and it must run for a minimum of ten min...

Page 31: ...l is extremely important for Optimizing the effectiveness of the sanitizer Maintaining water that is comfortable for the user Preventing equipment deterioration C If the spa water s pH level is too lo...

Page 32: ...nal sanitizer will be needed A weekly shock treatment is required The shock treatment quickly destroys any remaining contaminants while revitalizing the bromine in the water To weekly shock treat your...

Page 33: ...tizing the water Granulated bromine is preferred because it is totally soluble dissolves quickly and is nearly pH neutral C Maintaining the proper level of bromine during use is extremely important D...

Page 34: ...ering and swimming apparel which retains soap after washing Foam inhibitors can suppress foam but cannot remove soap from the water Soap is very difficult to remove from the water because soap is not...

Page 35: ...shell and damage the underside of the cover Automatic floating dispensers have a tendency to either over brominate or under brominate as the rate of erosion varies greatly Damage to the spa and cover...

Page 36: ...such large amounts Answer While over exposure to any chemical can be unhealthy many low levels of chemicals are effective and beneficial In the case of spa water the chemicals recommended in the Calde...

Page 37: ...not designed specifically use of the spa in a non residential application damage caused by operation of the spa at water temperatures outside the range of 35 F and 120 F damage caused by a dirty clogg...

Page 38: ...erly positioned Dirty filter Summer Timer on Set control panel to a higher temperature Align spa cover Clean filter Turn summer timer mode to off position Pump motor will not function Motor overload c...

Page 39: ...cludes the docking station related components and speakers to be free from defects in materials and workmanship for one year EXTENT OF WARRANTY This warranty extends only to the original consumer purc...

Page 40: ...lbs 115 lbs per square foot 230 volt 30 or 50 amp Single phase GFCI protected circuit Kauai 7 0 x 5 5 29 50 square feet 4 300 220 gallons 610 lbs 2 970 lbs 100 lbs per square foot 230 volt 30 or 50 a...

Reviews: