FIlTer MaInTenanCe

At least once a week, check and clean the skimmer basket and weir to ensure proper 

filter flow. Remove leaves, foreign matter, and debris. It is very important to keep your spa 

filter cartridge clean and free of particles to ensure proper water flow. A clean filter permits 

the hydrotherapy system to function properly and also allows more efficient filter cycles. 

Depending on how frequently your spa is used, we recommend cleaning the spa filter 

cartridge every four weeks. If this is not done, the filter may clog and restrict water flow, which 

causes improper filtration and poor jet performance.

IMPORTANT: 

The frequency and duration of use, and the number of occupants all contribute 

to determining the appropriate time between filter cleanings. More use means that more 

frequent filter cleanings will be required.

FIlTer CarTrIDGe reMOVal anD CleanInG 

InsTruCTIOns

Turn off power to the spa.

1. 

Push the filter basket down slightly and turn counter-clockwise to unlock. Then pull out 

2. 

the basket and weir.
Carefully pull up the filter cartridge and bring it out of the spa.

3. 

Always clean the filter using a filter degreaser to remove mineral and oil build-up. Soak 

4. 

the filter in the degreaser (according to the package directions).  Then place the filter on 

a clean surface and, using a garden hose, spray until it is clean. It may be necessary to 

rotate the filter while spraying to remove any debris lodged between the filter pleats.
Replace the cartridge in the spa.  To return the basket and weir, insert and rotate 

5. 

clockwise to lock into position. 
Turn on power to the spa.

6. 

NOTE: 

Replacement filter cartridges are available from your Caldera

®

 dealer. Refer to the 

back of this manual to determine the appropriate size for your spa.

DIVerTer ValVe MaInTenanCe

If your spa’s diverter valves become difficult to turn, it is likely that sand or grit has become 

lodged inside the valve body. It is very important that this debris is removed as soon as possible to avoid damage to the valve. To clean the valves, follow these steps:

Turn off power to the spa.

1. 

Remove the diverter valve’s handle by pulling upward while rocking it back and forth.

2. 

Unscrew the cap ring.

3. 

Remove the valve body by pulling it upward.

4. 

Wipe the valve body and the interior walls of the valve clean.

5. 

Lubricate the o-rings with a waterproof lubricant available from your Caldera dealer.

6. 

Reassemble the valve and turn on power to the spa.

7. 

VersassaGe 

®

 JeTs MaInTenanCe

If the VersaSsage jets spin slower than when the spa was new, or the jets are sticking, it may be due to a build-up of deposits inside the jet bearings. To remove the 

deposits, follow these instructions:

With the spa off, rotate the VersaSsage jet face counter-clockwise until it stops.

1. 

Once the face stops rotating, use a little extra force to rotate the face counter-clockwise past the locking position until it stops. Pull the face away from the spa.

2. 

After flushing the bearings inside the body with water, spin the rotating nozzle. It should spin freely. If it does not, place the bearing end in a cup of vinegar (the 

3. 

vinegar will soften any deposits). Let it soak overnight. The next day, flush with water and repeat the spin test. 

NOTE

: If it still doesn’t spin freely, then a second night of soaking is required. Replace the jet if the bearing still does not spin.  

To replace, position the face body downward and push the face body back into the jet fitting. Slightly rotate face body in either direction until you feel the body align 

4. 

with the fitting, and then press firmly on the face. Once seated, rotate the face clockwise using a little extra force to overcome the locking position. If the face does 

not rotate, remove and rotate the face 180°, and repeat this step.
Turn the jet pump on.  The VersaSsage jet should spin freely.

5. 

MAINTENANCE

FLOATING WEIR

BASKET

FILTER 

CARTRIDGE

STANDPIPE

PLEATS

Summary of Contents for paradise series

Page 1: ......

Page 2: ...HONE ___________________________________________ SPA MODEL SERIAL NUMBER ____________________________ COVER SERIAL NUMBER ________________________________ In most cities and counties permits will be r...

Page 3: ...rol Option Wireless System Only 20 EQUIPMENT COMPARTMENT Jet Pump Side 21 Controls Side 22 MAINTENANCE Filter Maintenance 23 Filter Cartridge Removal and Cleaning Instructions 23 Diverter Valve Mainte...

Page 4: ...ructions per electrical configuration 230 volt permanently installed models A ground terminal is provided on the terminal block located inside the control box To reduce the risk of electric shock conn...

Page 5: ...spa some medication may cause a user to become drowsy while other medication may affect heart rate blood pressure and circulation Persons taking medications which induce drowsiness such as tranquilize...

Page 6: ...ide Opening of the control box by the spa owner will void the warranty If you have an operational problem carefully go through the steps outlined in the Troubleshooting section If you are not able to...

Page 7: ...gularly to ensure proper levels of sanitizers pH and other water care requirements Drain clean and refill your spa with fresh water on a regular schedule and in accordance with this owner s manual Cle...

Page 8: ...lve 1 Temperature Sensor 2 Euro Directional Jet 3 VersaSsage 4 Jet AdaptaFlo 5 Jet Euphoria 6 Jet Diverter Valve 7 Drain 8 Ozone Jet Heater 9 return Control Panel 10 Pillow 11 Filter Compartment 12 Ac...

Page 9: ...ew Air Control Valve 1 Euro Directional Jet 2 Temperature Sensor 3 AdaptaSsage 4 Jet AdaptaFlo 5 Jet VersaSsage 6 Jet Diverter Valve 7 Drain 8 Speaker Optional 9 Ozone Jet 10 Control Panel 11 Heater r...

Page 10: ...3 4 13 2 14 OVERHEAD VIEW Air Control 1 Euro Directional Jet 2 Euro Pulse 3 Jet VersaSsage 4 Jet Diverter Valve 5 Drain 6 Speaker Optional 7 Ozone Jet Heater 8 Return Control Panel 9 Pillow 10 Filter...

Page 11: ...to TB 1 terminal 6 5 Connect the 10 AWG WHITE wire from the subpanel 30 amp breaker terminal N load neutral to TB 1 terminal 7 6 Connect the 10 AWG GREEN wire from the subpanel GROUND bar to TB 1 syst...

Page 12: ...m WARNING THE EXACT PHYSICAL LOCATION OF THE TERMINALS ON THE GFCI BREAKER WILL VARY BETWEEN MANUFACTURERS CONNECTING THE HOT WIRE TO THE NEUTRAL TERMINAL WILL CAUSE IRREVERSIBLE DAMAGE TO THE CONTROL...

Page 13: ...ter and the equipment compartment door is secured power must be applied to the spa Activate power to the subpanel from the main house panel first Open the door of the electrical subpanel and reset the...

Page 14: ...the face of the VersaSsage AdaptaSsage and AdaptaFlo jets to close the ones that are not in use TIP Turn both pumps on and place the diverter valves to the Mid Position then experiment with each of t...

Page 15: ...be adjusted to provide either a stationary direct stream or by positioning the nozzle to one side or the other a rotating jet stream The VersaSsage jets allow you to regulate the force of the massage...

Page 16: ...Jet System 2 4 Euro Directional jets in footwell Located in LumbarSsage Seat back right 5 Euro Directional jets 2 VersaSsage jets Located in front right seat 2 AdaptaFlo jets 1 VersaSsage jet Combinat...

Page 17: ...aFlo jet Jet Pump 2 Jet System 1 Located in UltraMassage lounge front 6 Sole Soothers 3 VersaSsage jets 2 Euro Directional jets Waterfall Combination Jet System Jet Pump 2 diverter in mid position act...

Page 18: ...csta Seat 8 Euro Directional jets 2 Euro Pulse jets Jet Pump Jet System 1 Located in UltraMassagelounge 6 Sole Soothers 3 VersaSsage jets 2 Euro Directional jets Located in LumbarSsage seat 4 Euro Dir...

Page 19: ...up and used the last temperature value set by the user will be stored in memory If power is disconnected from the spa it will automatically revert to the last set temperature when power is reapplied T...

Page 20: ...music on however when the system mode is deactivated the wireless music system will turn off To activate the system mode perform the following functions Press the MODE button until SYSTM is displayed...

Page 21: ...e the SPA LOCK feature When the Spa Lock is activated the buttons for the JETS LIGHTS temperature control and any other features your spa may have are deactivated To deactivate the Spa Lock press the...

Page 22: ...display AUDIO 1 Press the ON button to display PWR 2 Press the MODE to display VOL 3 Press the MODE to display SETUP 4 Press the ON button to display EQ 5 Press the ON button for EQ Press OFF button f...

Page 23: ...Pump 2 Salina Martinique only 2 Ozone Injector Included with the Optional Monarch 3 CD Ozone Generator kit Unions 4 Temperature Sensor 5 Pump Drain Plug 6 5 2 3 6 1 4b Discharge 4a Suction JET PUMP S...

Page 24: ...22 EQUIPMENT COMPARTMENT 1 2 3 4 Advent 1 Control Box System EnergyPro 2 Circulation Pump EnergyPro 3 Heater Monarch 4 CD Ozone Generator optional CONTROLS SIDE...

Page 25: ...o turn it is likely that sand or grit has become lodged inside the valve body It is very important that this debris is removed as soon as possible to avoid damage to the valve To clean the valves foll...

Page 26: ...Winterizing your spa If you leave the spa unused for a long period of time in severely cold weather you should drain the spa and winterize it to avoid accidental freezing due to a power or equipment...

Page 27: ...e spa pillows 1 Carefully lift one end of the pillow away from the spa shell 2 Continue lifting one end until all pillow retainers are released from the pillow IMPORTANT Just pulling the pillow straig...

Page 28: ...n Do not let the vinyl dry with a soap film on it before it can be rinsed clean Scrub the cover s perimeter and side flaps Rinse clean with water 4 Rinse off the underside of the cover with water only...

Page 29: ...mprove water clarity Ozone Ozone is a powerful oxidizing agent which is produced in nature and artificially by man Ozone forms no by products of chloramines ozone actually oxidizes chloramines and wil...

Page 30: ...aser liquid stain and scale inhibitor and liquid de foamer must always be added directly into or in front of the filter compartment while a jet pump is running and it must run for a minimum of ten min...

Page 31: ...l is extremely important for Optimizing the effectiveness of the sanitizer Maintaining water that is comfortable for the user Preventing equipment deterioration C If the spa water s pH level is too lo...

Page 32: ...nal sanitizer will be needed A weekly shock treatment is required The shock treatment quickly destroys any remaining contaminants while revitalizing the bromine in the water To weekly shock treat your...

Page 33: ...tizing the water Granulated bromine is preferred because it is totally soluble dissolves quickly and is nearly pH neutral C Maintaining the proper level of bromine during use is extremely important D...

Page 34: ...ering and swimming apparel which retains soap after washing Foam inhibitors can suppress foam but cannot remove soap from the water Soap is very difficult to remove from the water because soap is not...

Page 35: ...shell and damage the underside of the cover Automatic floating dispensers have a tendency to either over brominate or under brominate as the rate of erosion varies greatly Damage to the spa and cover...

Page 36: ...such large amounts Answer While over exposure to any chemical can be unhealthy many low levels of chemicals are effective and beneficial In the case of spa water the chemicals recommended in the Calde...

Page 37: ...not designed specifically use of the spa in a non residential application damage caused by operation of the spa at water temperatures outside the range of 35 F and 120 F damage caused by a dirty clogg...

Page 38: ...erly positioned Dirty filter Summer Timer on Set control panel to a higher temperature Align spa cover Clean filter Turn summer timer mode to off position Pump motor will not function Motor overload c...

Page 39: ...cludes the docking station related components and speakers to be free from defects in materials and workmanship for one year EXTENT OF WARRANTY This warranty extends only to the original consumer purc...

Page 40: ...lbs 115 lbs per square foot 230 volt 30 or 50 amp Single phase GFCI protected circuit Kauai 7 0 x 5 5 29 50 square feet 4 300 220 gallons 610 lbs 2 970 lbs 100 lbs per square foot 230 volt 30 or 50 a...