Symbol Glossary 

The following is an explanation of symbols that may be used on Caldera Medical’s products and packaging: 

 

Symbol 

Title/ Meaning/ Referent 

Function/ Description 

ISO 7000 

Reg. no. 

ISO 15223-

1 or Other 

Manufacture

 

 

Manufacturer 

Indicates the medical device manufacturer. 

3082 

 

5.1.1 

 

EU Authorized Representative 

Indicates the authorized representative in the European community.  

N/A 

5.1.2 

 

Date of Manufacture 

Indicates the date when the medical device was manufactured. 

2497 

5.1.3 

 

Use by Date 

Indicates the date after which the medical device is not to be used. 

2607 

5.1.4 

 

Batch Code 

Indicates the manufacturer's batch code so that the batch or lot can be 

identified. 

2492 

5.1.5 

 

Catalogue number 

Indicates the manufacturer's catalogue number so that the medical device can 

be identified. 

2493 

 

5.1.6 

Sterility

 

 

Sterilized Using Ethylene Oxide 

Indicates a medical device that has been sterilized using ethylene oxide. 

2501 

5.2.3 

 

Do Not Re-sterilize 

Indicates a medical device that is not to be re-sterilized. 

2608 

5.2.6 

 

Do Not Use If Package Is Damaged 

Indicates a medical device that should not be used if the package has been 

damaged or opened. 

2606 

5.2.8 

 

Non-sterile 

Indicates a medical device that has not been subjected to a sterilization process.  2609 

5.2.7 

Storage

 

 

Keep Dry 

Indicates a medical device that needs to be protected from moisture. 

0626 

5.3.4 

 

Temperature Limit 

Indicates the temperature limits to which the medical device can be safely 

exposed 

0632 

5.3.7 

 

Humidity Limitation 

Indicates the range of humidity to which the medical device can be safely 

exposed 

2620 

5.3.8 

Safe Use 

 

Do Not Re-use 

Indicates a medical device that is intended for one use, or for use on a single 

patient during a single procedure. 

1051 

5.4.2 

 

Consult Instructions for Use 

Indicates the need for the user to consult the instructions for use. 

1641 

5.4.3 

 

[IFU URL] 

Consult Instructions for Use, or 

For Instructions for Use Refer to 

Indicates the need for the user to consult the instructions for use and where the 

electronic instructions for use (eIFU) and symbols glossary can be found. 

1641 

5.4.3 

 

Follow Instructions for Use 

Refer to Instruction manual/booklet; on medical electrical equipment, Follow 

Instructions for Use 

ISO 7010-

M002 

N/A 

 

Caution 

Indicates the need for the user to consult the instructions for use for important 

cautionary information such as warnings and precautions that cannot, for a 

variety of reasons, be presented on the medical device itself. 

0434A 

5.4.4 

 

General Warning 

General Warning Sign 

N/A 

ISO 7010-

W012 

 

Type BF Applied Part 

Signifies Applied Part Type 

N/A 

IEC 60517-

5840 

IPX2 

Ingress Rating 

Signifies that the device is rated to level 2 for water ingress protection, and that 

water splashing against the enclosure from any direction shall have no harmful 

effect. 

N/A 

N/A 

 

Non-Ionizing Electromagnetic 

Radiation 

Indicates generally elevated, potentially hazardous levels of non-ionizing 

radiation, or to indicates equipment or systems e.g. in the medical electrical area 

that include RF transmitters or that intentionally apply RF electromagnetic 

energy for diagnosis or treatment. 

N/A 

IEC 60417-

5140 

 

NRTL Certification 

Signifies that the device meets regulatory and performance requirements 

verified by NRTL 

N/A 

N/A 

Other

 

 

Packaging Unit 

Indicates the number of pieces in the package. 

2794 

N/A 

 

Prescription Only 

Requires prescription in the United States of America. 

N/A 

21 CFR 

801.109 

Summary of Contents for Benesta CAL-TR1511

Page 1: ...ns for Use CAL TR1511 1 pack CAL TR1513 3 pack Manufactured by Caldera Medical Inc 5171 Clareton Drive Agoura Hills CA 91301 U S Toll Free 866 4 CALDERA Telephone 818 879 6555 Fax 818 879 6556 www cal...

Page 2: ...Not Re use Indicates a medical device that is intended for one use or for use on a single patient during a single procedure 1051 5 4 2 Consult Instructions for Use Indicates the need for the user to...

Page 3: ...presence of cancer cells Exercise extreme caution when resecting tissue in patients who have implants that extend into the uterine cavity Do not use the BenestaTM Tissue Removal Device to resect tissu...

Page 4: ...e IV Pole pressure cuff or fluid management system FMS Distending media Vacuum source suction canister and tissue trap BenestaTM Hysteroscope and outflow channel Inflow tubing Y tubing Hysteroscope an...

Page 5: ...ng hard into target pathology Excessive leverage on the device does not improve cutting performance and may result in decreased performance and or unintended excision of tissue pathology 13 Excised ti...

Page 6: ...to earth Not Applicable device is battery operated Radio Frequency RF Common Mode IEC 61000 4 6 3 Vms 150kHz to 80MHz Not Applicable device is battery operated Power Frequency Magnetic Field IEC 61000...

Page 7: ...by Caldera Medical at its option of any product found to be defective during the warranty period Damage inflicted to a product by the user will result in additional charges and may void the warranty T...

Reviews: