CAL
-SERIES
22
Figure 17. TYPICAL GARAGE INSTALLATION
10.0
SUSPENSION OF HEATER:
10.1
HORIZONTAL INSTALLATION
Locate suspension points on ceiling or roof. Heater is suspended at standard 10' (3m) intervals (refer to Figure
19). Adequately secure chains to beam (refer to Figure 18) Suspension Points. Hang chains down from
suspension point to desired level. Heater is to be hung level.
NOTE:
Front & rear end caps are double chained.
SUSPENSION POINTS
Figure 18. EXAMPLE SUSPENSION DETAILS
WARNING:
It is the responsibility of the installer to use hanging chain that is a minimum of
2/0 or with a minimum support capacity of no less than 75 lbs. Also make sure all suspension
points are adequate to support weight of heater and any accessories. Also make sure all S-
Hooks are affixed properly and the open ends squeezed closed. If the suspension system
fails, it is the responsibility of the installer. A failed suspension system can cause property
damage, severe injury and/or death.