2010 Barbecue Grills
LTR20101038, Rev. A
Appendix
www.calflamebbq.com
27
Disconnect or shut off the liquid propane or
1.
natural gas line connect to the grill. Wait until
the burners cool down.
Open the hood and remove the grate and flame
2.
tamer on top of the burner you want to replace.
Through the access door underneath the grill,
3.
find the round stud and locking pin that locks the
burner you want to replace.
Carefully remove the locking pin with your
4.
fingers.
Raise the stud from the locking hole and move
5.
the burner forward carefully to release it from
the ignition and gas supply valve.
Take the burner out of the grill and store it in a
6.
safe and dry place.
Install the burner. Align the gas inlet on the
7.
burner with the gas supply valve on the grill and
torch tube with ignition. Make sure they align
perfectly. Slide the stud at the other end into the
locking hole.
Adjust the infrared burner. Make sure the burner
8.
is aligned and in position.
Repeat steps 2 through 9 if you want to replace
9.
other burners.
Put back the grate you just removed. (You don’t
10.
need the flame tamer for infrared burners.)
Reconnect or turn on the gas line.
11.
If you want to change back to regular burners, just
follow the procedure above in reverse order.
Installing and Replacing Infrared Burners
BTU Ratings
Main burners
15,000 BTU
1.9mm
Infrared burner CF 3 – 5
9,000 BTU
#54 DMS
Infrared burner CF 4
12,000 BTU
#52 DMS
Side burner
13,000 BTU
#50 DMS
Summary of Contents for BBQ00841P-20