4 - ENG    PN 21033264 B | User Manual

HELiOS 300 & 800

WARNING:

 DO NOT SMOKE WHILE 

OPERATING THE UNIT.

WARNING:

 DO NOT ALLOW SMOK-

ING, CANDLES, OR OPEN FLAMES IN 
THE SAME ROOM WITH THE DEVICE.

WARNING:

 SMOKING WHILE 

WEARING AN OXYGEN CANNULA 
CAN CAUSE FACIAL BURNS AND 
POSSIBLY RESULT IN DEATH.

WARNING:

 REMOVING THE CAN-

NULA AND PLACING IT ON CLOTH-
ING, BEDDING, SOFAS, OR OTHER 
CUSHION MATERIAL WILL CAUSE A 
FLASH FIRE WHEN EXPOSED TO A 
CIGARETTE, HEAT SOURCE, SPARK 
OR FLAME. 

WARNING:

 IF YOU SMOKE PLEASE: 

(1) TURN OFF THE HELIOS PORTABLE, 
(2) TAKE OFF THE CANNULA, AND 
(3) LEAVE THE ROOM WHERE THE 
DEVICE IS LOCATED.
WARNING: KEEP YOUR UNIT IN A 
WELL-VENTILATED AREA. DO NOT 
STORE LIQUID OXYGEN EQUIPMENT 
IN A CLOSET, CAR TRUNK, OR OTHER 
CONFINED AREA. DO NOT PLACE 
BLANKETS, DRAPERIES, OR OTHER 
FABRICS OVER EQUIPMENT. THIS 
WILL CAUSE AN OXYGEN ENRICHED 
ATMOSPHERE WHICH IS A FIRE 
HAZARD.
WARNING: DO NOT CARRY THE POR-
TABLE UNIT UNDER YOUR CLOTH-
ING. DO NOT STORE LIQUID OXYGEN 
EQUIPMENT IN A CLOSET, CAR 
TRUNK, OR OTHER CONFINED AREA. 
DO NOT PLACE BLANKETS, DRAP-
ERIES, OR OTHER FABRICS OVER 
EQUIPMENT. THIS WILL CAUSE AN 
OXYGEN ENRICHED ATMOSPHERE 
WHICH IS A FIRE HAZARD.
WARNING: IN THE EVENT OF AN 
ACCIDENTAL TIP-OVER, IMMEDI-
ATELY BUT CAUTIOUSLY RETURN THE 
UNIT INTO AN UPRIGHT POSITION IF 
POSSIBLE. IF ANY LIQUID OXYGEN IS 
ESCAPING, LEAVE THE AREA IMME-
DIATELY AND CALL YOUR HEALTH-
CARE PROVIDER. DO NOT ATTEMPT 
TO MOVE THE UNIT OR STOP THE 
LIQUID OXYGEN FROM ESCAPING.

WARNING: DO NOT TOUCH FROSTED 
PARTS OF ANY UNIT.

WARNING: DO NOT STORE OR 
OPERATE THE HELIOS PORTABLE 
COUPLED TO YOUR RESERVOIR.
WARNING: THIS PRODUCT CAN 
EXPOSE YOU TO CHEMICALS IN-
CLUDING NICKEL, WHICH IS KNOWN 
TO THE STATE OF CALIFORNIA TO 
CAUSE CANCER.  FOR MORE INFOR-
MATION, GO TO WWW.P65WARN-
INGS.CA.GOV.

Caution:

 A caution identifies a po-

tentially hazardous situation which, 
if not avoided, may result in minor 
or moderate injury to the user or 
damage to the equipment or other 
property.

Caution: 

RX Only. Federal law restricts this 

device to sale by or on the order of a physician.

Caution:

 Use the H300/H850 Portable only as 

directed by your doctor.

Caution:

 If the unit has been dropped, please 

contact your health care provider to ensure the 
unit is still in working condition.

Caution:

  Do not allow untrained personnel to 

handle or operate this device.

Note: Notes provide important information about 
using the equipment properly.
Note: Use of this device is prohibited on commercial 
passenger and cargo air flights by the Federal Avia-
tion Administration.
Note: Applicable EMC information can be found in 
the Companion Portable Technical Service Manual 
at www.CAIREmedical.com.

Summary of Contents for HELiOS Marathon

Page 1: ...HELiOSTM Series User Manual English...

Page 2: ...prohibited Reg P003 Do not smoke near unit or while operating unit Reg P002 Type BF applied part degree of protection against electric shock Reg 5333 Warning Reg W001 Council Directive 93 42 EEC conc...

Page 3: ...ctive 2012 19 EU waste electrical and electronic equipment WEEE WEEE IEC 60601 1 Medical electrical equipment Part 1 General requirements for basic safety and essential performance Drip Proof This pro...

Page 4: ...AUTIOUSLY RETURN THE UNIT INTO AN UPRIGHT POSITION IF POSSIBLE IF ANY LIQUID OXYGEN IS ESCAPING LEAVE THE AREA IMME DIATELY AND CALL YOUR HEALTH CARE PROVIDER DO NOT ATTEMPT TO MOVE THE UNIT OR STOP T...

Page 5: ...d as a conserving or continuous flow device and holds 0 84 liters of liquid oxygen It provides continuous flow from 1 6 LPM and demand flow on settings of 1 4 H300 and H850 portable units shown Specif...

Page 6: ...rap 5 Contents Indicator Window 6 Vent Valve Lever 7 Fill Connector QDV Fill Connector Compatibility The H300 and H850 can be filled from any CAIRE top fill TF reservoir that has a CAIRE style male fi...

Page 7: ...through top port Breath is detected through bottom port Operating Instructions Filling 1 Clean the fill connectors on the H300 H850 and the reservoir with a clean dry lint free cloth WARNING THE FILL...

Page 8: ...T LEAVE THE AREA AND CALL YOUR HEALTH CARE PROVIDER IMMEDIATELY WARNING IF LARGE AMOUNTS OF VAPOR ARE ISSUING FROM THE UNITS DURING FILLING STOP FILLING LEAVE THE ROOM AND CALL YOUR HEALTH CARE PROVID...

Page 9: ...continuous flow the H300 H850 will deliver a steady stream of oxygen You must continue to breathe through the nasal cannula normally to continue receiving continuous flow Note Due to the possibility...

Page 10: ...pres ent from humidified exhaled gas Replacing the cannula with a dry one enhances the ability of the Portable to pulse Ensure that the cannula is not kinked Ensure that the cannula tips remain in you...

Page 11: ...r always wipe the male fill connector on the Reservoir and the female fill connector on the Portable with a clean dry cloth before filling NOTE It is recommended that routine maintenance be performed...

Page 12: ...with no further obligation or consequence All rights not expressly stated herein are reserved by us as applicable www cairemedical com CAIRE Inc 2200 Airport Industrial Dr Ste 500 Ball Ground GA 3010...

Reviews: