background image

2 - ENG    PN 21033264 B | User Manual

HELiOS 300 & 800

Symbols Glossary

ISO 7000; Graphical symbols for use on equip-
ment—Index and synopsis

Read user’s manual before operation. 

Reg. # 1641

Operating temperature limitation of 

these units is 14°F to 104°F (-10°C to 

40°C). Storage temperature limitation 

range is -40°F to 158°F (-40°C to 

70°C). Reg. # 0632

Keep away from rain, keep dry. Reg. 

# 0626

Name and address of manufacturer. 

Reg. # 3082

 

 

Caution, consult accompanying docu-

ments. Reg. # 0434A

Catalog Number. Reg. # 2493

Serial Number. Reg. # 2498

This way up. Reg. # 0623

Fragile, handle with care. Reg. # 

0621

ISO 7010: Graphical symbols—Safety colors 
and safety signs—Registered safety signs

Frostbite may occur on contact with 

cold liquid or gaseous oxygen, or 

frosted parts. Warning low tempera-

ture. To warn of low temperature or 

freezing conditions. Reg. # W010
Keep away from open flame, fire, 

sparks. Open ignition source and 

smoking prohibited. Reg. # P003

Do not smoke near unit or while 

operating unit. Reg. # P002

Type BF applied part (degree of 

protection against electric shock). 

Reg. # 5333

Warning. Reg. # W001

Council Directive 93/42/EEC; concerning medi-
cal devices

Authorized representative in the 

European Community
This device complies with the 

requirements of Directive 93/42/EEC 

concerning medical devices. It bears 

the CE marking as shown.

This device complies with the re-

quirements of Directive 2010/35/EU 

concerning medical devices.  It bears 

the pi marking as shown.

ADR: European Agreement concerning the 
International Carriage of Dangerous Goods 
by Road

Non-toxic gas.

Hazard Oxidizing substances: fire 

intensifying risk. Oxidizing agents 

cause fires to burn more vigorously.
Refrigerated Liquid, USP; Produced 

by Air Liquefaction

Internal Symbols

Keep unit well ventilated at all times

Keep away from flammable materials, 

oil and grease.

Portable Empty

Portable Full

Always keep Portable in one of the 

following positions: upright, flat on 

its back, or any position in between.

Wipe connector with clean dry cloth 

before filling.

Summary of Contents for HELiOS Marathon

Page 1: ...HELiOSTM Series User Manual English...

Page 2: ...prohibited Reg P003 Do not smoke near unit or while operating unit Reg P002 Type BF applied part degree of protection against electric shock Reg 5333 Warning Reg W001 Council Directive 93 42 EEC conc...

Page 3: ...ctive 2012 19 EU waste electrical and electronic equipment WEEE WEEE IEC 60601 1 Medical electrical equipment Part 1 General requirements for basic safety and essential performance Drip Proof This pro...

Page 4: ...AUTIOUSLY RETURN THE UNIT INTO AN UPRIGHT POSITION IF POSSIBLE IF ANY LIQUID OXYGEN IS ESCAPING LEAVE THE AREA IMME DIATELY AND CALL YOUR HEALTH CARE PROVIDER DO NOT ATTEMPT TO MOVE THE UNIT OR STOP T...

Page 5: ...d as a conserving or continuous flow device and holds 0 84 liters of liquid oxygen It provides continuous flow from 1 6 LPM and demand flow on settings of 1 4 H300 and H850 portable units shown Specif...

Page 6: ...rap 5 Contents Indicator Window 6 Vent Valve Lever 7 Fill Connector QDV Fill Connector Compatibility The H300 and H850 can be filled from any CAIRE top fill TF reservoir that has a CAIRE style male fi...

Page 7: ...through top port Breath is detected through bottom port Operating Instructions Filling 1 Clean the fill connectors on the H300 H850 and the reservoir with a clean dry lint free cloth WARNING THE FILL...

Page 8: ...T LEAVE THE AREA AND CALL YOUR HEALTH CARE PROVIDER IMMEDIATELY WARNING IF LARGE AMOUNTS OF VAPOR ARE ISSUING FROM THE UNITS DURING FILLING STOP FILLING LEAVE THE ROOM AND CALL YOUR HEALTH CARE PROVID...

Page 9: ...continuous flow the H300 H850 will deliver a steady stream of oxygen You must continue to breathe through the nasal cannula normally to continue receiving continuous flow Note Due to the possibility...

Page 10: ...pres ent from humidified exhaled gas Replacing the cannula with a dry one enhances the ability of the Portable to pulse Ensure that the cannula is not kinked Ensure that the cannula tips remain in you...

Page 11: ...r always wipe the male fill connector on the Reservoir and the female fill connector on the Portable with a clean dry cloth before filling NOTE It is recommended that routine maintenance be performed...

Page 12: ...with no further obligation or consequence All rights not expressly stated herein are reserved by us as applicable www cairemedical com CAIRE Inc 2200 Airport Industrial Dr Ste 500 Ball Ground GA 3010...

Reviews: