background image

TABLE OF CONTENTS

 

 

General Information ............................................ 4

 

Warning and Caution Statements ..................... 4

 

Introduction to the Eclipse 5 Oxygen System ... 6

 

Eclipse 5 Oxygen System Specifications .......... 7

 

Pulse Dose Mode Specifications ...................... 8

 

Power Accessory Specifications ....................... 8

 

AC Power Supply .......................................... 8

 

DC Power Supply .......................................... 8

 

Power Cartridge (Battery) ............................. 8

 

Independent Safety Testing ................................ 9

 

Electromagnetic Compatibility ........................ 10

 

Guidance and 

Manufacturer’s Declarations .... 10

 

How The Eclipse 5 Works .................................... 12

 

Introduction ..................................................... 12

 

ATF

® 

Concentrator Module .............................. 12

 

Compressor and Compressor Enclosure ........ 13

 

Power Distribution ........................................... 13

 

Control Board ................................................. 13

 

Control Panel .................................................. 14

 

User Controls & System Status Indicators ...... 14

 

Continuous Flow Mode ................................... 15

 

Pulse Dose Mode ........................................... 15

 

Provider Mode Functions ................................ 16

 

Alarm Code ................................................. 16

 

Pulse Mode Sensitivity Adjustment ............. 16

 

Hours of Operation ..................................... 16

 

9V Battery Status ........................................ 16

 

Rise Time (Bolus Delivery) ......................... 16

 

Software Version ........................................ 16

 

Service Mode Functions ................................. 17

 

Eclipse 5 Data Acquisition Tool (EDAT) ...... 17

 

Power Supplies ............................................... 18

 

AC Power Supply ........................................ 18

 

DC Power Supply ........................................ 18

 

Power Cartridge .............................................. 19

 

Typical New Power Cartridge Operation Time
 .................................................................... 20

 

Charging Algorithm ...................................... 22

 

Training The Patient ........................................... 23

 

Introduction ..................................................... 23

 

Pre-Delivery Check List ................................... 23

 

Indications for Use .......................................... 24

 

Contraindications ............................................ 24

 

Basic Concept Training ................................... 24 
Safety Guidelines and Operational Safety 
Warnings/Caution ............................................ 24 
Locating the Eclipse 5 for Proper Use and 
Ventilation

 

 ........................................................................ 25 
 
The Users Manual ........................................... 25 
Showing Panel Buttons, Indicators, Alerts and 
Alarms ............................................................. 25

 

Showing Power Cartridge Power Level ........... 26

 

Selecting the Proper Flow Mode and Setting .. 26

 

Selecting Continuous Flow Mode .................... 26

 

Selecting Pulse Dose Mode ............................ 26 
“P

ower

 Cartridge (Battery) C

onservation

” Feature

 ........................................................................ 27

 

Adjusting the Pulse Mode Sensitivity Setting .. 27

 

Adjusting Rise Time ........................................ 28

 

Connecting the AC Power Supply ................... 28

 

Connecting the DC Power Supply ................... 29

 

Active Lifestyle Training ................................... 29

 

Attach the Universal Cart ............................ 30

 

Using Around the House ............................. 30

 

Traveling by Vehicle .................................... 30

 

Traveling by Air ........................................... 32

 

Traveling by Cruise Ship ............................. 32

 

Traveling by Train ........................................ 32

 

Eclipse 5 Maintenance .................................... 33

 

Weekly Maintenance

—Patient .................... 33

 

Clean the Air Inlet Filter ............................... 33

 

Cl

ean

 

and

 C

are

 

for the

 Tubing 

and

 C

a

nnul

a

 .. 33

 

Summary of Contents for Eclipse 5 with autoSAT

Page 1: ...Eclipse 5 with autoSAT Oxygen Concentrator TECHNICAL SERVICE MANUAL...

Page 2: ...AC Power Supply 18 DC Power Supply 18 Power Cartridge 19 Typical New Power Cartridge Operation Time 20 Charging Algorithm 22 Training The Patient 23 Introduction 23 Pre Delivery Check List 23 Indicati...

Page 3: ...ication Tests 48 Record Hours of Operation Software Version 49 Electrical Safety Test 50 Cleaning the Eclipse 5 50 Provider Service and Maintenance Record 51 Shipping and Transporting the Eclipse 5 52...

Page 4: ...rinciples of operation Providers are given proper guidance in the use of the Eclipse 5 and its accessories that can beconveyed to patients Providers are made aware of the care diagnostics maintenance...

Page 5: ...rd commercial aircraft Flow Setting Indicator Pulse Mode Operation Device operating normally power button Increase Flow Setting Decrease Flow Setting ISO 7000 Graphical symbols for use on equipment In...

Page 6: ...RIDGE BATTERY PN 7082 SEQ PN 20852326S with IEC type A cord 20852325S with IEC type C cord and 20852324S with IEC type G cord two LED model Oxygen Outlet Port Control Panel FAA Approval Icon Rating La...

Page 7: ...0 LPM Continuous Flow 3 0 Pulse Dose Mode 48 dB A 40 dB A Less than 57 dB while alarming Operating Environment Temperature Humidity 50 F to 104 F 10 to 40 C 10 to 95 Non condensing 82 4 F 28 C Maximu...

Page 8: ...w at the last Continuous Flow setting After another 15 seconds the Eclipse 5 stops delivering Continuous Flow and waits 15 seconds for a breath The Eclipse 5 will stay in this modality until a breath...

Page 9: ...gnetic Compatibility Emissions EN55011 FCC Part J15 Class B Conducted EN55011 FCC Part J15 Class B Radiated EN61000 3 2 EN61000 3 3 EN61000 4 2 EN61000 4 3 EN61000 4 4 EN61000 4 5 EN61000 4 6 EN61000...

Page 10: ...provided in this manual Portable and mobile RF communications equipment can affect Medical Electrical Equipment The use of Accessories transducers and cables other than those specified with the excep...

Page 11: ...ons it is recommended that the Eclipse 5 is powered from an uninterruptible power supply UPS Power frequency magnetic field IEC 61000 4 8 30A m Power frequency magnetic fields should be at levels char...

Page 12: ...nd controls both the power source and the Power Cartridge charger Figure 1 Eclipse 5 System Block Diagram ATF CONCENTRATOR MODULE The Eclipse 5 uses a passive system to separate oxygen from air Air fl...

Page 13: ...sor enclosure serves to efficiently draw cooling air in over the compressor cylinders while simultaneously pushing exhaust gas out of the concentrator POWER DISTRIBUTION The Power Manager takes extern...

Page 14: ...ng has been saved and will be used at start up Power Cartridge battery Status Gauge This indicator displays the charge remaining in the battery Each of the five horizontal gray bars represents approxi...

Page 15: ...y rates Regardless of setting the pulse profile is a simple square wave pulse based on a 16 mL volume Refer to Pulse Profiles table below Pulse durations are no less than 100 milli seconds at the begi...

Page 16: ...S x PS 1 is the most sensitive setting PS 3 is the least sensitive setting Factory default is PS 2 HOURS OF OPERATION The Eclipse 5 hour meter provides valuable information on hours of operation Provi...

Page 17: ...t needs EDAT software is capable of sensing and displaying historical event logs and values of components and sensors within the Eclipse 5 system This can be used to determine system faults or user er...

Page 18: ...t is illuminated when the AC Power Supply is supplying 28VDC power If the LED is not illuminated there is no input power available In addition the Power Supply contains protection circuits for output...

Page 19: ...f the user If the Eclipse 5 power cartridge is being charged the battery symbol will display with a waterfall animation However if the power cartridge is not charging then the battery symbol will rema...

Page 20: ...d with the Eclipse 5 is not fully charged Before using the Eclipse 5 Oxygen System for the first time the Power Cartridge must be fully charged Store the power cartridge in a cool dry location Do not...

Reviews: