CMxx60
DB9
CM3160P
、
CM6560P
CMxx50-SERVER
DB9
CM3150P-SVR,CM6550P-SVR,CM8150P-SVR,CM8250P-SVR,CM8
350P-SVR,CM510-21H-SVR,CM510-21T-SVR,CM510-21F-SVR
3. Enter Configuration State:
1
)
Choose corresponding serial port, set baud rate to 115200bps, data bits to 8, parity to
NONE,stop bits to 1, and flowctrl to NONE.
2
)
Choose
Configuration
in
General
.
3
)
Click
Open
to open serial port.
4
)
Power DTU according to the cue.
5
)
You can configure parameters after there is a cue of
Load Parameter:Success!
5 Details of Configuration
5.1 Basic Conf
At this page, there are some basic configuration parameters. If there is no special requirements or just
for a test, you can configure DTU quickly by it.
5.1 .1 Instruction of Basic Conf
Basic Conf’s Interface: