Selected Model
Interface
Type
Product Model
CMxx50
DB9
CM3150P,CM6550P,CM8150P,CM8250P,CM8350P,CM510-21H,
CM510-21T,CM510-21F
CMxx60
DB9
CM3160P
、
CM6560P
CMxx50-SERVER
DB9
CM3150P-SVR,CM6550P-SVR,CM8150P-SVR,CM8250P-SVR,CM8
350P-SVR,CM510-21H-SVR,CM510-21T-SVR,CM510-21F-SVR
Remark: you can find the corresponding models in configuration log.
Operation:
Click the Model:
Then you can see:
After choosing one of them, the corresponding model will be listed in the data logging option
box. For example, if you choose
, then the available model will be
listed. As follows:
4. In the area of “Parameter of serial port”, please set “Port” to which is used to connect
DTU and computer; set “Baud Rate” to 115200 and “Parity” to NONE; “StopBits” to 1;
“FlowCTRL” to NONE. Then open the port.
5. After step four, it will appear a cue of “Please power on the device” in “Log display area”.
As follows:
Please power the DTU or re-power it.
6. Please choose “Configuration” in “work state” of “General” which inside the area of
“ Configuration mode switch”. Then it will enter configuration state.