厦 门 才 茂 通 信 科 技 有 限 公 司
Xiamen Cai
more
Communication Technology Co.,Ltd
Add: 3F, 1st Building, 23# Wanghai Road, Xiamen
Tel: +86-592-5902655
Web:
http://en.cai
more.
com
Fax:+86-592-5975885
29
Maximum
Allowable ID
Client Timeout
Time
xx50-SERVER
Server-DTU
will
disconnect
the
connection with a client-DTU if the
client-DTU’s data-send interval more than
the value of this parameter.
Authentication
ID
xx50-SERVER
When it is set as 1, server-DTU will
check the client-DTU’s ID, if the value is
within the range of
Minimum Allowable
ID
and
Maximum Allowable ID
,
then
server-DTU will agree the connection
request.
If this parameter is set as 0, server-DTU
will consent to all connection requests.
0=No,
1=Yes
Replace Client
xx50-SERVER
If the value of this parameter is set to Yes,
when there is a connection request from
one client-DTU whose ID is same as the
ID of one of connected client-DTUs, then
server-DTU
will
disconnect
the
connection with previous DTU and
connect the current DTU.
0=No,
1=Yes
We suggest that set this parameter to
1 for there is a situation that when a
client-DTU reconnect server, then it
may take up two places if the
Replace
Client
is set as 0(No).
Broadcast
Transmitting
Data
xx50-SERVER
If the value is set as 1, server-DTU will
send data to all connected client-DTU by
broadcast.
0=No,
1=Yes
Keep Online
Interval
xx50-SERVER
Server-DTU will visit the
Keep Online
Address1-3
when it is over the interval.
The unit is ms, and range is 0~65535.
Keep Online
Retry Count
xx50-SERVER
The number of attempts that server-DTU
to try to visit
Keep Online Address
.
The range is 1~65535.
Keep Online (IP)
Address 1~3
xx50-SERVER,
xx60
The website that the server-DTU tries to
visit to judge whether it is online.
LCP Retry
Interval
xx50-SERVER
LCP is Link Control Protocol. The
parameter is used to judge whether
client-DTU is online. Server-DTU will
send a LCP to client-DTU in each interval.
The unit is second.
We suggest to not to use it.
LCP Number of
Retries
As same as
Keep Online Retry Count
.
Keep Online
xx50-SERVER
If there is no client-DTU connect The unit is minute.