4
Rev022520
Installation
Clearance opening measured
from inside edge of baseplate
to baseplate
CONCRETE FLOOR ANCHOR INFO:
MIN. 3000 PSI CONCRETE
4" MIN. CONCRETE THICKNESS
3" MIN. EDGE DISTANCE (ALL SIDES)
Step 1
Illustration
VI. Smart Gate Installation
NOTICE
Refer to parts list on Page 3 for part item numbers and descriptions.
NOTICE
Base plates are slotted to allow adjustment for alignment.
STEP 1.
Mark holes for the Gate Post and anchor with concrete floor anchors. Measure and mark the center of the
wall opening, using the Gate Size Reference Table to assist in centering the gate on the wall opening. (Gate
Size Reference Drawing on Page 15).
Door Opening
this side of
Gate Post
SG SIZE REFERENCE TABLE
CLEAR OPENING WIDTHS
CLEARANCE HEIGHT
SG-60-PCY*
48”, 54” 60”, 66”, 72”, OR 78”
94
1
/
4
” - 124
1
/
4
”
Red
Decal
1
9.5
*SG-60-PCY:
a. Adjustable from a minimum of 48” to a maximum 78” clear opening.
b. Gate will fit 48”, 54”, 60”, 66”, 72” and 78” doors.
IMPORTANT!
Follow Anchor Manufacturer's technical data manual/installation instructions for installation
requirements and proper installation procedures.
Field concrete foundation design and complete consolidation of concrete surrounding embedded
item(s) anchorage points
NOT
by PS Safety Access
.
© CAI Safety Systems | (951) 465-7386 | https://caisafety.com | [email protected]