background image

1

Installation Instructions/Operation and Maintenance Manual

Patent Pending

Table of Contents:

Safety Precautions ............................................................. 2

Product Information ........................................................... 2

Installation Instructions ..................................................... 4

Disassembling of Gate .....................................................12

Operation ..........................................................................13

Replacement Parts List ...................................................14

Size Reference Drawing ...................................................15

Inspection and Maintenance...........................................16 

Warranty Certificate

 .........................................................19

Models: 

 SG-60-PCY 

 

*

Refer to page 15 for required size dimensions.

Contact Information

IMPORTANT! 

Read entire Instruction and Operations Manual to become familiar with the product.

NOTICE

 

This product is a fall protection product. The effectiveness of the product is directly related to the proper 

installation and operation of this product. Failure to properly maintain this product 

will

 

affect performance.

Publication Notice

This manual has been compiled and published covering the latest product descriptions and specifications.

The contents of this manual and the specifications of this product are subject to change without notice.

 

PS Safety Access™ reserves the right to make changes without notice in the specifications and materials contained 

herein and shall not be responsible for any damages (including consequential) caused by reliance on the materials 

presented, including but not limited to typographical and other errors relating to the publication.

PS Safety Access and/or its respective suppliers may make improvements and/or changes in the product(s)/ 

service(s) offered and/or the program(s) at any time without notice.

Retain this manual for future reference.

If you would like to download a copy of this manual, please go to pssafetyaccess.com

Product registration is an essential step to protecting your product, register Online at 

psindustries.com/contact/register-your-product/

 

Cantilever Gate System

 

Single Opening Cantilever Gate 

 

© CAI Safety Systems | (951) 465-7386 | https://caisafety.com | [email protected]

CAI Safety Systems 
555 Monica Circle, Corona CA 92880 

 

Phone Main: (951) 465-7386 

Fax: (951) 405-2796

Website: https://caisafety.com 
E-mail: [email protected] 

  

Hours of Operation: 8am to 5pm (Pacific) Mon - Fri

Summary of Contents for SG-60-PCY

Page 1: ...ect to change without notice PS Safety Access reserves the right to make changes without notice in the specifications and materials contained herein and shall not be responsible for any damages includ...

Page 2: ...ions in this manual II Operation Guidelines A The Smart Gate is designed to meet OSHA Railing Standard 1910 29 b B Operation in a manner other than intended could result in damage or less than accepta...

Page 3: ...part list below Smart Gate Part List As shipped ITEM DESCRIPTION QTY 1 LDSG GATE POST 1 2 LDSG GATE CATCH 1 3 LDSG ADJ CLEVIS PCY 1 4 LDSG 2 LIFT ARM 5FT 2 5 LDSG 1 75 LIFT ARM 5FT 2 6 LDSG GATE END 1...

Page 4: ...able to assist in centering the gate on the wall opening Gate Size Reference Drawing on Page 15 Door Opening this side of Gate Post SG SIZE REFERENCE TABLE CLEAR OPENING WIDTHS CLEARANCE HEIGHT SG 60...

Page 5: ...lock nut Step 3 Illustration A Step 3 Illustration B STEP 2 Attach Adjustable Clevis red decal with 2 3 8 x 4 hex bolts 2 3 8 nylock nuts and 4 3 8 flat washers a Tighten bolts bracket height will be...

Page 6: ...at finish do not slide beyond desired length STEP 4 Slide 1 3 4 Lower Lift Arm green decal into 2 Lift Arm red decal to the desired gate width a Insert 3 8 x 2 1 4 hex bolts aligning with pre drilled...

Page 7: ...Adjustable Clevis red decal on Gate Post b Insert 3 8 x 3 hex bolt and tighten 3 8 nylock nut 4 9 1 9 11 9 3 Red Decal Red Decals STEP 7 Slide 1 3 4 Upper Lift Arm blue decal into 2 Lift Arm red deca...

Page 8: ...nment STEP 9 Mark out holes for the Gate Catch and anchor with concrete floor anchors STEP 8 Use rubber mallet to gently hammer flange bearings into both sides of 1 3 4 Upper Lift Arm a Slide the Gate...

Page 9: ...3 4 Lift Arm a Insert 3 8 x 2 1 4 hex bolt and tighten 3 8 nylock nut Step 11 Illustration B STEP 10 Add bumpers to Lower Lift Arms at both locations and snug with 1 4 bolts and 1 4 nylock capped nuts...

Page 10: ...rom concrete floor anchors to free up the assembly and lay on the ground in the extended position for improved access during dampener installation NOTICE To protect the Powder Coat finish lay on cardb...

Page 11: ...upward anchor Gate Post back onto the floor surface and tip gate down into Gate Catch As the gate approaches fully closed you should hear a loud noise of the dampener self setting STEP 15 Visually ve...

Page 12: ...TION STEPS 13 15 TO INSTALL NEW DAMPENER AS SHOWN IN THIS OPERATIONS AND MAINTENANCE MANUAL STEP 2 Rotate gate to the open position gate arms vertical before proceeding with Step 3 CAUTION CAUTION Hig...

Page 13: ...der an Edge SafeTM Lockout Kit part 514582 Gate lifts vertically a full 90 without Pinch Points Uniquely placed Dampener is mounted high up to prevent potential Pallet and Forklift damage Counter bala...

Page 14: ...Yellow For EdgeSafeTM Lockout Kit order part 514582 Kit includes 1 Storage Bracket 1 Lock Pin 2 Bolts 2 Nylock Nuts and Installation Instructions TO ORDER PARTS CONTACT PS SAFETY ACCESS AT 877 446 151...

Page 15: ...ce Height CLEAR OPENING 8 8 8 8 X SG Size Reference Drawing SG Size Reference Table CLEAR OPENING WIDTHS CLEARANCE HEIGHT SG 60 PCY 48 54 60 66 72 OR 78 94 1 4 124 1 4 CAI Safety Systems 951 465 7386...

Page 16: ...eners at four corners of the gate can be tightened to reduce closing speed 4 If gate closes too slowly fasteners at four corners of the gate can be loosened to increase closing speed C Finishes 1 Insp...

Page 17: ...spect at minimum annually Date Installed Product Model Number Serial Number Opening Identifier Number Location DATE INSPECTED INSPECTED BY Print Sign INSPECTION ITEMS NOTED CORRECTIVE ACTION CORRECTED...

Page 18: ...ed Inspect at minimum annually Date Installed Product Model Number Serial Number Opening Identifier Number Location DATE INSPECTED INSPECTED BY Print Sign INSPECTION ITEMS NOTED CORRECTIVE ACTION CORR...

Page 19: ...chase Contact PS Industries at the address shown below PS Industries Incorporated Toll Free 877 446 1519 Attention Warranty Phone 701 746 4519 1150 S 48th Street Fax 701 746 8340 Grand Forks ND 58201...

Page 20: ...psindustries com contact register your product Distributed by CAI Safety Systems 1609 S Grove Ave Ste 104 Ontario CA 91761 64 Phone 951 465 7386 Fax 951 405 2796 Email webstore caisafety com Website...

Reviews: