ENCORE GROUND Rev. 1 2021-10
37
www.cafection.com 800-561-6162
SERVICE & INSTALLATION MANUAL for Cafection's Encore Ground
S
e
r
v
ic
e Mo
d
e
6.4
Password Pop-Up
This pop-up window will appear when pressing the Recipes,
System or Audits tabs. The user needs to type in his
password using the alphanumeric keyboard, then press on
ENTER. Depending on the password entered, the user will
gain access to different tabs.
6.5
Recipes Tab
To access the screen below, press the SW1 button (white) on the main board inside the brewer's
door (see section 3.6) and select the Recipes tab.
6.5.1 Blend Sub Tab
The customization sub tab allows the user to edit blends name or label. For each blend,
it is possible to display only one option (name or label) on the beverage settings screen.
Default blends names are Coffee 1 and Coffee 2.
Coffee names and labels can be edited with Sophia (Optimum License required).
1. Use the "Tag" button to select a tag
for the associated blend. Use the
"Name" button to edit the blend
name using the text box.
2. These buttons are used to save
or discard any changes to the
customization settings. Any
unsaved changes will be lost.
1
2
Recipe name
Blend name or label
Labels list