ZEFIRO
3
- ZEN AIRTIGHT
36
PROBLEM
CAUSE
SOLUTION
INTERVENTION
The stove is at its
highest power but
does not heat up.
Ambient tempera-
ture reached.
The stove is at its minimum value. Increase the desired am-
bient temperature.
Stove running and
display showing
"Smoke Overtepe-
rature"
Reached fume
outlet limit tempe-
rature
The stove runs at minimum. NO PROBLEM!
The stove's smoke
duct produces
condensation
Low smoke tempe-
rature
Check that the flue is not clogged.
Increase stove power to minimum (pellet drop and fan revs).
Install condensation collection cup.
Stove running and
display showing
"SERVICE"
Routine main-
tenance alert (it
does not block the
system)
When this flashing message appears upon start-up, it means
that the preset operating hours have elapsed before mainte-
nance. Contact the service centre.
“Pellet reserve
enabling” activates
with the tank full
Failure to reach the
threshold tem-
perature, large or
poor quality pellet,
clogged fume
passage
Increase pellet with “Pellet Recipe” or clean the combustion
chamber
9
TECHNICAL DATAS
9.1
FUSE REPLACEMENT
For fuse replacement in the electric socket which stands on the back of the stove, extract the fuses to change with the aid of a
screwdriver for opening the shutter (see
Fig. 102
).
Fig. 102 - Shutter with fuses to remove