12
Fig. 12 - Phase1
Fig. 13 - Phase 2
Fig. 14 - Phase 3
• Remove the ring inside the combustion air fitting (see
Fig. 12
and
Fig. 13
).
• Insert the concentric pipe as in
Fig. 14
.
5
INSTALLATION
5.1
INTRODUCTION
• The assembly position must be chosen depending on environment, outlet, chimney flue.
• Check with local authorities if there are any restrictive regulations which regard the combustible air inlet, room ventilation,
fume exhaust system together with chimney flue and chimney pot.
• Check if there is the combustible air inlet.
• Check the probable presence of other stoves or appliances which could depress the room.
• Check at switched on stove if there is the presence of CO in the room.
• Check if the chimney has the necessary draught.
• Check if during the fume passage all has been executed in safety (probable fume losses and distances from flammable mate-
rials, etc.…).
• The installation of the appliance must enable an easy access for appliance, fume exhaust pipes and chimney flue cleaning.
• The installation must enable en easy access to the electric connection plug (see
ELECTRIC CONNECTION a pag. 19
).
• To install more appliances, the external air inlet must be correctly dimensioned (see
FEATURES a pag. 37
).
5.2
OVERALL DIMENSIONS
Fig. 15 - General dimensions: Zefiro
3
, Zen Airtight
LEGEND
Fig. 15
1
69,7 cm
2
49 cm