21
SHELL - BREEZE
7.5
FEED SCREW MAINTENANCE
Proceed as follows for the feed screw maintenance:
Fig. 44 - Screw removal
Fig. 45 - Coque removal
Fig. 46 - Gear motor removal
• Enter the tank and loosen the 4 screws of the feed screw coque (see
Fig. 44
).
• Remove the coque (see
Fig. 45
).
• Remove the gear motor by loosening the locking screw (see
Fig. 46
).
Fig. 47 - Spiral removal
Fig. 48 - Bearing removal
• Remove the spiral (see
Fig. 47
).
• If worn, remove the bearing (see
Fig. 48
) and replace it.
• To reassemble, proceed in reverse order.
7.6
FUME PIPES ANNUAL CLEANING
Clean annually from soot with brushes.
The cleaning operation must be executed by a specialized stove-repairer who will provide for the cleaning of fume pipe, chimney
flue and chimney pot. He will also check their eficiency and will release a written declaration of the safety of the appliance. This
operation must be executed at least once a year.
7.7
GASKET REPLACEMENT
In case of deterioration of fire door, hopper or fume chamber gaskets, it is necessary to replace them by an autorized technician in
order to guarantee the good running of the stove.
Use exclusively original spare parts.