Once the exchanger cleaning has been finished, you must remove the four screws fixing plates “C” to the structure, remove gasket
“D” and then clean the lower compartment where all ash deposits from previous cleaning operations have accumulated (see
Fig.
40
). Remove the screws fixing plate “E” to the structure, clean the fan with the brush and vacuum any residue (see
Fig. 41
). If
necessary, replace gasket “D”.
Check the ceramic fibre gasket seal on the stove door. If necessary, order new gaskets from the dealer for replacement or contact
an authorised service centre to perform the entire operation.
Fig. 40 - Plate removal
Fig. 41 - Cleaning
The fume exhaust system cleaning frequency depends on stove use and its installation. We recommend con-
tacting an authorised service centre for the end-of-season cleaning and maintenance operations because the
centre will perform an overall check of the parts, as well as the above-mentioned operations.
7.4
LOWER COMPARTMENT CLEANING
Once the combustion chamber cleaning is finished, we recommend cleaning the G grid on the stove back (see
Fig. 42
) and the V
fans to remove any dust or dirt, in order to guarantee high performance (see
Fig. 43
).
Every year, clean the room fan to remove ash or dust causing unbalance of the blades and greater noise.
Fig. 42 - Back grid
Fig. 43 - Fans
LEGEND
Fig. 42 - Fig. 43
G
Grid
V
Fans