new RIVER IDRO T2 - TESIS Airtight T2 - MIRA T2 - MAYA idroT2
47
14 FEATURES
DESCRIPTION
RIVER IDRO 16-T2
RIVER IDRO 23-23H2O-T2
WIDTH
53 cm
53 cm
DEPTH
52 cm
52 cm
HEIGHT
110 cm
110 cm
WEIGHT
136 kg
136 kg
Effective rated power (H
2
O)
12,9 kW (11.094 kcal/h)
18 kW (11.094 kcal/h)
Minimum effective power (H
2
O)
3,4 KW
2,3 KW
Maximum operating pressure
2 bar – 200 kPa
2 bar – 200 kPa
INTRODUCED THERMIC POWER (Min/Max)
5,1 - 17,1 kW
5,1 - 24,3 kW
NOMINAL THERMIC POWER (Min/Max)
4,9 - 16,1 kW
4,9 - 22,4 kW
EFICIENCY (Min/Max)
96,7 - 93,7 %
96,7 - 92 %
FUME TEMPERATURE (Min/Max)
55 - 116 °C
55 - 153 °C
FUME MAXIMUM LOADING CAPACITY (Min/Max)
4,5 - 9,8 g/s
4,5 - 12,1 g/s
CO EMISSIONS (13% O
2
) (Min/Max)
0,012 - 0,008 %
0,012 - 0,010 %
OGC EMISSIONS (13% O
2
) (Min/Max)
3 - 2 mg/Nm
3
3 - 2 mg/Nm
3
NO
X
EMISSIONS (13% O
2
) (Min/Max)
94 - 95 mg/Nm
3
94 - 99 mg/Nm
3
Medium CO CONTENTS at 13% O
2
(Min/Max)
150 - 100 mg/Nm
3
150 - 136 mg/Nm
3
Medium POWDER CONTENTS at 13% O
2
(Min/Max)
18 - 13 mg/Nm
3
18 - 14 mg/Nm
3
CHIMNEY DEPRESSION (Max)
12 Pa - 2 Pa***
12 Pa - 2 Pa***
ON SHARED CHIMNEY FLUE
NO
NO
FUME OUTLET DIAMETER
Ø80 mm
Ø80 mm
COMBUSTIBLE
Pellet Ø6-7 mm
Pellet Ø6-7 mm
PELLETS HEATING VALUE
5 kWh/kg
5 kWh/kg
PELLETS HUMIDITY
≤ 10%
≤ 10%
HEATING VOLUME 18/20°C Coeff. 0,045 kW (Min/Max)
137 - 451 m
3
**
137 - 627 m
3
**
HOURLY CONSUMPTION (Min/Max)
1 - 3,6 kg/h*
1 - 5,1 kg/h*
HOPPER CAPACITY
22 kg
22 kg
RANGE (Min/Max)
22 - 6 h
22 - 4 h
SUPPLY
230 V - 50 Hz
230 V - 50 Hz
POWER INPUT (Max)
343 W
343 W
INGNITER RESISTANCE POWER INPUT
300 W
300 W
MINIMUM EXTERNAL AIR INLET (last effective area)
80 cm
2
80 cm
2
STOVE WITH SEALED CHAMBER
YES
YES
EXTERNAL AIR INLET FOR SEALED CHAMBER
60 mm
60 mm
DISTANCE FROM COMBUSTIBLE MATERIAL (back/side/bottom)
200 / 300 / 0 mm
200 / 300 / 0 mm
DISTANCE FROM COMBUSTIBLE MATERIAL (ceiling/front)
- / 1000 mm
- / 1000 mm
* Values that can vary depending on the type of pellet used
** Heatable volume depending on the power required per m
3
(respectively, 40-35-30 Kcal/h per m
3
)
*** Value recommended by the manufacturer (not binding) for optimal product performance
Tested according to EN 14785 in compliance with the European Construction Product regulation (EU 305/2011)
Summary of Contents for RIVERIDRO 16 T2