Fig. 80 - Clean with pipe cleaner
Fig. 81 - Vacuum out the ash
Fig. 82 - Clean with pipe cleaner
• Clean with a pipe cleaner and suction any ash accumulated inside
• After cleaning, repeat the operation in reverse making sure the gasket is intact and efficient: if necessary, provide for the
replacement with original spare parts.
Fig. 83 - Vacuum out the ash
Fig. 84 - Vacuum out the ash
9.7
REPLACING THE OVERPRESSURE RELIEF VALVE FOR THE COMBUSTION CHAMBER
Combustion chamber overpressure rubber spacer “G” (fig.A) may become worn and/or damaged, thereby requiring replacement
once a year to ensure proper system operation.
Replace by following the instructions below:
• Remove the top
• Remove the first ceramic or steel side panel (depending on the type of stove)
• Unscrew the screw-washer-rubber spacer-roller shown in fig.A/C (on both sides of the cover). Then assemble the new kit:
• Align the screw-washer-rubber spacer-roller as shown in fig.C and screw it into the structure.
• Tighten the screw completely.
Now make sure that rubber spacer compression is correct, using the template supplied with the kit:
• Place the template on the cover (fig.B); the head of the screw must barely touch the upper reference. Otherwise, tighten or
loosen the screw until it does.