PROBLEM
CAUSE
SOLUTION
INTERVENTION
The stove is at its
highest power but
does not heat up.
Ambient temperatu-
re reached.
The stove is at its minimum value. Increase the desired ambient
temperature.
Stove running and
display showing
"Smoke Overtepe-
rature"
Reached fume outlet
limit temperature
The stove runs at minimum. NO PROBLEM!
The stove's smoke
duct produces
condensation
Low smoke tempe-
rature
Check that the flue is not clogged.
Increase stove power to minimum (pellet drop and fan revs).
Install condensation collection cup.
Stove running and
display showing
"SERVICE"
Routine maintenan-
ce alert (it does not
block the system)
When this flashing message appears upon start-up, it means that
the preset operating hours have elapsed before maintenance.
Contact the service centre.
11.2 PROBLEM SOLVING (THERMOSTOVE)
PROBLEM
POSSIBLE CAUSES SOLUTIONS
INTERVENTION
In automatic
position, the boiler
always works at
maximum power
Thermostat set to
the minimum
Reset the thermostat temperature.
Room thermostat
in a position that
always detects cold.
Change the position of the thermostat
Faulty temperature
detection probe.
Check and, if necessary, replace the probe
Faulty circuit board
Replace board
The boiler does not
start
Power failure
Make sure the power cable is plugged in and the main switch is in
the “I” position.
Blown fuse
Replace the fuse.
Clogged smoke duct
or exhaust
Clean the smoke exhaust and/or smoke duct.
Water temperature
probe has tripped
Call customer service