background image

new RIVER IDRO T2 - TESIS Airtight T2 - MIRA T2 - MAYA idroT2

31

SETTING

VALUES

ROOM TEMP.

Cannot be activated

EXTERNAL THERMOSTAT

ON (connect storage tank thermostat)

SEASON

WINTER (summer cannot be activated) 

AUTO ECO

ON (it may not be disabled)

BOILER WATER TEMP. SETTING

80 °C (to be adjusted according to the temperature chosen for the storage tank)

Parameters to set

SETTING

VALUES

CONFIGURATION

4

Hydraulic diagram

Fig. 68 - Configuration 4

LEGEND

Fig. 68

1

Stove

2

Cold H2O manifold

3

Hot H2O manifold

4

3-way valve

5

Electronic board

6

Zone valve

7

Radiator

8

Storage tank

9

Thermostat

10

Release pump

11

Room thermostat

12

Expansion vessel

A

Room thermostat independent from the stove (to be connected to the zone valves, if necessary)

B

Thermostat to be connected directly to the electronic board (see electrical system)

Disconnect any three-way valve and stove internal flow switch, if equipped with a DHW kit.

Summary of Contents for RIVERIDRO 16 T2

Page 1: ...STALLER MANUAL PELLETTHERMOSTOVE EN OriginalInstructions 2022CADELsrl Allrightsreserved Tuttiidirittiriservati new RIVERIDRO 16T2 23T2 23H2 OT2 MIRA 16T2 22T2 TESIS 16 23 AIRTIGHTT2 MAYA IDRO 16T2 24T...

Page 2: ...NNECTION 20 7 3 TOP OUTLET CONNECTION IDRO MAYA 16 24 20 8 PLUMBING CONNECTION 21 8 1 PLUMBING SYSTEM CONNECTION 21 8 2 CONNECTION DIAGRAM RIVER IDRO 16 23 MIRA 16 22 TESIS 16 23 AIRTIGHT 21 8 3 CONNE...

Page 3: ...e product is packaged in a recyclable cardboard box according to RESY standards on a wood pallet All the packaging materials can be reused for similar purposes or in the event disposed of as waste ass...

Page 4: ...ightlevelsothatthesmokeductandpipearecoaxial If the stove needs to be connected to an exhaust pipe that goes through the back wall to go into the flue be extremely careful not to force it Forcingthest...

Page 5: ...must be moved with the utmost care 3 CHIMNEY FLUE 3 1 PREPARING THE SMOKE EXPULSION SYSTEM The combustion product expulsion system is a particularly important element for the proper operation of the...

Page 6: ...with 1 union 6 5 mt 10 mt Maximum length with 3 unions 4 5 mt 8 mt Maximum number of unions 3 3 Level section minimum inclination 3 4 mt 4 mt Installation at a height above 1200 m a s l NO Obligatory...

Page 7: ...t least double the internal section of the chimney prevent the penetration of rain or snow ensure the outlet of smoke even in the event of wind windproof chimneypot the height of outflow must be beyon...

Page 8: ...ence of other suction devices e g vmc electric fan for stale air extraction kitchen hood other stoves etc in the same room or in communicating rooms of the same housing unit could cause negative press...

Page 9: ...d duct 50 mm 60 mm 1 m 80 mm 3 m 1 m 100 mm 7 m 4 m Fig 10 Directairinflow Fig 11 Airinletforsealed chamberinstallation LEGEND Fig 10 Fig 11 1 Roomtoventilate 2 Externalairinlet 4 Shieldgrid 5 Curvein...

Page 10: ...ood etc In both cases install suitable insulation between the flue and the ceiling Always check and comply with the plate data of the flue specifically the minimum safety distances from combustible ma...

Page 11: ...ccording to EN 13384 1 which is resistant to soot fire and which complies with the distances prescribed by the combustible materials indicated on the plate data there is a suitable combustion air flow...

Page 12: ...e present such as furniture curtains or sofas as a precaution increase the stove clearances substantially to avoid possible deterioration due to the effect of heat Fig 14 Safetydistancesfromcombustibl...

Page 13: ...ator 1 by at least 50 cm from adjacent walls without emptying the system e g by using a double shut off gate or suitable flexible connection 1 The national reference standard for the installation of d...

Page 14: ...5cm 5 13cm 6 37 5cm 7 46cm 8 Scaricofumid 8cm 9 Presaariacomburented 5cm 10 Scaricofumisuperiored 8cm 11 10 5cm 12 40 5cm 6 4 STOVE DOOR REMOVAL INSTALLATION For some operations e g side panel assemb...

Page 15: ...ethegrate Fig 22 Positiontheframe Secure the strut with screws see Fig 20 Work on a table Secure the grate with screws on the upper front see Fig 21 Hook the frame to the stove see Fig 22 Fig 23 Secur...

Page 16: ...panel by unscrewing the 4 screws Fig 27 Secure the top panel to the support with the screws and screw the grid back into place Fig 28 Fig 26 Removethepanel Fig 27 Removethegrid Fig 28 Securethepanelto...

Page 17: ...Fig 36 Securingthepanel 6 8 MAYA IDRO 16 24 FRAME ASSEMBLY To assemble the frame proceed as follows Fig 37 Securethestrut Fig 38 Securethegrate Fig 39 Unscrewthescrew Secure the strut with screws see...

Page 18: ...ame to the stove see Fig 41 Parts of gear joints Fig 42 Fig 43 2 Slot Fig 44 3 Slot Fig 45 4 Slot 6 9 ASSEMBLING TESIS 16 23 AIRTIGHT To assemble the side panels proceed as follows Fig 46 Removethescr...

Page 19: ...authorizedtechnician The electric connection occurs through a cable with plug put in an electric socket which is able to support charge and tension specific of every model as described in the technica...

Page 20: ...ed to these devices 7 SMOKE OUTLET CONNECTION IDRO MAYA 16 24 7 1 GENERAL WARNINGS The stove can have a rear or top smoke outlet You must purchase the elbow rear outlet or the straight pipe top outlet...

Page 21: ...peration iftheaforementionedwarningsarenotcompliedwith IMPORTANT WESTRONGLYRECOMMENDWASHINGTHEENTIRESYSTEMBEFORECONNECTINGTHESTOVEINORDERTORE MOVERESIDUEANDBUILD UPS Always install gate valves upstrea...

Page 22: ...ng B 139 C 330 Aquos3 16 23 B 120 C 312 Idroprince3 16 23 B 106 5 C 298 7 Idron16 22Airtight B 106 5 C 298 7 Tesis16 23Airtight B 106 5 C 298 7 Mira16 22 8 3 CONNECTION DIAGRAM RIVER IDRO 23 H2O Fig 5...

Page 23: ...a safety valve that can be inspected on the back of the stove under the pump IT IS MANDATORY to connect a rubber hose thatisresistanttotemperaturesupto110 C notsupplied tothesafetyexhaustandrunittothe...

Page 24: ...with all heating appliances to seal micro fractures that cause small and inaccessible leaks 8 7 FILLING THE SYSTEM To fill the system the stove may be equipped with a terminal optional with a non ret...

Page 25: ...rnal room thermostat DHW production for boiler or storage tank with EXTERNAL thermostat CONNECTEDTOTHE ELECTRONIC BOARD optional DISCONNECT ANY 3 WAYVALVES AND INTERNAL FLOW SWITCHES 3 Room temperatur...

Page 26: ...Expansionvessel A Wiring diagram for connecting external thermostat and zone valve in the case of several val ves connectinparallel B Wiringdiagramforconnectingtheexternalthermostat 8 11 CONFIGURATION...

Page 27: ...SON WINTER summer may be activated AUTO ECO OFF with winter setting ON with summer setting cannot be deactivated Parameters to set SETTING VALUES CONFIGURATION 2 Hydraulic diagram Fig 65 Configuration...

Page 28: ...el If the external thermostat is used activate the EXT THERMOSTAT function on the control panel and con nectitdirectlytotheelectronicboard seeelectricalsystembelow Adjustable setting SETTING VALUES RO...

Page 29: ...ippedwithaDHWkit 8 12 CONFIGURATION 3 8 12 1 System with direct pellet stove and room probe or external thermostat optional with external DHW production controlled by box probe optional All activities...

Page 30: ...rconnectingtheexternalthermostat C NTCprobetobeconnecteddirectlytotheelectronicboard seeelectricalsystem D 3 wayvalvetobeconnecteddirectlytotheelectronicboard seeelectricalsystem Disconnectanythree wa...

Page 31: ...age tank Parameters to set SETTING VALUES CONFIGURATION 4 Hydraulic diagram Fig 68 Configuration4 LEGEND Fig 68 1 Stove 2 ColdH2Omanifold 3 HotH2Omanifold 4 3 wayvalve 5 Electronicboard 6 Zonevalve 7...

Page 32: ...d out by authorised personnel Adjustable setting SETTING VALUES ROOMTEMP Cannot be activated EXTERNALTHERMOSTAT ON connect storage tank probe SEASON WINTER summer cannot be activated AUTO ECO ON it ma...

Page 33: ...nternalflowswitch ifequippedwithaDHWkit 8 15 CONFIGURATION WITH STORAGE TANK AND AUXILIARY WALL MOUNTED BOILER EXAMPLE 8 15 1 System with pellet stove connected to a storage tank with auxiliary wall m...

Page 34: ...ing to the System configuration of the room probe placed on the rear of the appliance see drawing by the external thermo stat by the boiler water temperature or by the NTC probes Fig 71 Probeposition...

Page 35: ...corresponds with the smoke outlet pipe Plate L1 sup portsthefluepipeasitissecuredtothestoveusingthetwoscrews a Withthestoveinstalledyoumustonlyremoveplate L1 if the smoke pipe must be removed otherwi...

Page 36: ...apothrwisenoxiuousfumeswillpropagateamongtheroom 9 3 SMOKE EXTRACTOR COMPARTMENT CLEANING At the back of ash drawer D you will find smoke cover E which must be removed to clean the smoke extractor The...

Page 37: ...ns 9 5 DOOR CLOSING FUNCTIONALITY PERIODIC CHECK Check that door closing assures a correct seal by means of the paper sheet test and that when the door is closed the closing block X in the figure does...

Page 38: ...may become worn and or damaged thereby requiring replacement once a year to ensure proper system operation Replace by following the instructions below Remove the top Remove the first ceramic or steel...

Page 39: ...oT2 39 Fig 85 Rubberspacer Fig 86 Rubberspacer 10 BOILER HEAD CLEANING The boiler head has to be cleaned every year Fig 87 Unscrewscrewusing8mmspanner Fig 88 Removethehandle Fig 89 Unscrewscrewusing8m...

Page 40: ...of the safety of the appliance This operation must be executed at least once a year 10 2 GASKET REPLACEMENT Incaseofdeteriorationoffiredoor hopperorfumechambergaskets itisnecessary toreplacethembyanau...

Page 41: ...l display Faulty flat cable Replace the flat cable Faulty electronic board Replace the mother board Pellets do not reach the combustion chamber Empty hopper Full the hopper Open fire door or open pell...

Page 42: ...the stove burning pot obstructed holes with too ash remains Have the fan blades and auger cleaned see SMOKE RPMVARIATION User Manual Obstructed exhaust The exhaust chimney is partially or totally obs...

Page 43: ...block the system When this flashing message appears upon start up it means that the preset operating hours have elapsed before maintenance Contact the service centre 11 2 PROBLEM SOLVING THERMOSTOVE P...

Page 44: ...OSURE of the PIPE FITTINGS Radiators cold in the winter Room thermostat local or remote adjusted too low If remote thermostat check whether it is defective Adjust it to a higher temperature Replace it...

Page 45: ...ove Proceed as follows Remove the frame see the dedicated chapters After these operations you can have access at the following components geared motor ignition plug ambient fan fume fan ambient probe...

Page 46: ...STATCONNECTION TERMINALBLOCK 6 WATERSAFETYTHERMOSTAT 19 INTERNALROOMPROBE 7 CANDLE 20 PUFFER BOILERPROBECONNECTION TERMINALBLOCK 8 PELLETSAFETYTHERMOSTAT 21 BOILERWATERTEMPERATUREPROBE 9 AIRPRESSURE 2...

Page 47: ...IMNEY DEPRESSION Max 12 Pa 2 Pa 12 Pa 2 Pa ON SHARED CHIMNEY FLUE NO NO FUME OUTLET DIAMETER 80 mm 80 mm COMBUSTIBLE Pellet 6 7 mm Pellet 6 7 mm PELLETS HEATINGVALUE 5 kWh kg 5 kWh kg PELLETS HUMIDITY...

Page 48: ...ESSION Max 12 Pa 2 Pa 12 Pa 2 Pa ON SHARED CHIMNEY FLUE NO NO FUME OUTLET DIAMETER 80 mm 80 mm COMBUSTIBLE Pellet 6 7 mm Pellet 6 7 mm PELLETS HEATINGVALUE 5 kWh kg 5 kWh kg PELLETS HUMIDITY 10 10 HEA...

Page 49: ...HIMNEY DEPRESSION Max 12 Pa 2 Pa 12 Pa 2 Pa ON SHARED CHIMNEY FLUE NO NO FUME OUTLET DIAMETER 80 mm 80 mm COMBUSTIBLE Pellet 6 7 mm Pellet 6 7 mm PELLETS HEATINGVALUE 5 kWh kg 5 kWh kg PELLETS HUMIDIT...

Page 50: ...Y DEPRESSION Max 12 Pa 2 Pa 12 Pa 2 Pa ON SHARED CHIMNEY FLUE NO NO FUME OUTLET DIAMETER 80 mm 80 mm COMBUSTIBLE Pellet 6 7 mm Pellet 6 7 mm PELLETS HEATINGVALUE 5 kWh kg 5 kWh kg PELLETS HUMIDITY 10...

Page 51: ...NOTE...

Page 52: ...CADEL srl 31025 S Lucia di Piave TV Via Foresto sud 7 Italy Tel 39 0438 738669 Fax 39 0438 73343 www cadelsrl com www free point it www pegasoheating com Rev 00 2022...

Reviews: