Terminal Description
TERMINAL
DESCRIPTION
4- Pin Connector
Programmable Auxiliary Output Terminals
1
Connect one side of zone 1 loop. The other side of loop to common terminal 2. Open or
short causes alarm.
2
Common (-) Terminal
3
Connect one side of zone 2 loop. The other side of loop to common terminal 2. Open or
short causes alarm.
4-9
See Terminal Drawing and repeat the above sequence for zones 3-6.
10,11,12,13
Connect keypad wires as follows; yellow to terminal 17, green to terminal 18, black to
terminal 19, red to terminal 20. 200 ft. maximum run with 22 gauge wire, 500 ft. maximum
run with 18 gauge wire. Home run cable to each keypad.
14(-)& 15(+)
Siren driver output to speaker(s), (speaker rating should be 15 watt at 8 or 16 ohm, or 30/40
watt at 4, 8, or 16 ohms). If siren driver disable is selected in location 132, output becomes
voltage output, 12VDC, 1 Amp maximum load.
16(-)& 17(+)
Smoke detector power 12VDC, 100 mA maximum (For those jurisdictions which allow the
Priority zone to be used with smoke detectors.)
18(-)& 19(+)
Auxiliary power, regulated 12VDC, 500 mA maximum.
20
Earth Ground, connect to a cold water pipe or 6 to 10 foot driven rod.
21 & 22
AC input, connect a 16.5V 25 VA, Class II U.L. approved transformer (included) Tech Electro
P/N 48A0164 or 16.5VAC, 50VA, Electro Mec P/N LTS-5016.
T1
(T1) House Telephone Tip (Brown)
T
(T) Telephone Tip (Green)
R
(R) Telephone Ring (Red)
R1
(R1) House Telephone Ring (Gray)
Battery Leads
Battery leads Standby battery leads black(-) and red(+) connect to a 12VDC lead acid
rechargeable battery. Do not connect to a dry cell battery.
FUSE DESCRIPTION
FUSE #
F2
DESCRIPTION
SPEAKER / BELL
(2 AMP)