28
ARM/DISARM CODES 1 - 7
LOCATION
PAGE
DESCRIPTION
DATA 1
DATA 2
DATA 3
DATA 4
DEFAULT
000-003
10
User #1 Arm / Disarm Code
"1-2-3-4"
004-007
10
User #2 Arm / Disarm Code
"15" Disabled
008-011
10
User #3 Arm / Disarm Code
"15" Disabled
012-015
10
User #4 Arm / Disarm Code
"15" Disabled
016-019
10
User #5 Arm / Disarm Code
"15" Disabled
020-023
10
User #6 Arm / Disarm Code
"15" Disabled
024-027
10
User #7 Arm / Disarm Code
"15" Disabled
028-031
11
"Go To Program" Access Code
"9-7-1-3"
PHONE NUMBERS, ACCOUNT CODES & FORMATS
032-039
9
Primary Phone Number Digits 1 - 8
"0" Disabled
040-047
9
Primary Phone Number Digits 9 - 16
"0" Disabled
048-051
9
Primary Account Code
"0" Disabled
052
9
Primary Format
"0" Disabled
053
9
Secondary Phone Number As Back-up
"0" Enabled
054-061
9
Secondary Phone Number Digits 1-8
"0" Disabled
062-069
9
Secondary Phone Number Digits 9 - 6
"0" Disabled
070-073
9
Secondary Account Code
"0" Disabled
074
9
Secondary Format
"0" Disabled
CONTROL & COMMUNICATOR FEATURES
LOCATION
PAGE
DESCRIPTION
DATA
DEFAULT
075
11
Entry Delay Time (10 Second Increments)
"3" 30 Seconds
076
11
Exit Delay Time (10 Second Increments)
"6" 60 Seconds
077
11
Siren Shutdown / Recycle Time Out (2 Minute Increments)
"4" 8 Minutes
078
11
Zone 1 Type
"3" Entry / Exit
079
11
Zone 2 Type
Locations 078 - 083
"5" Int Follower
080
11
Zone 3 Type
DATA TYPE DATA TYPE
"6" Instant
081
11
Zone 4 Type
1 Day
Zone
6 Instant
"6" Instant
082
11
Zone 5 Type
2
24 Hour
7
24 Hr Silent
"6" Instant
083
11
Zone 6 Type
3 Entry/Exit
8 Fire
"6" Instant
084
11 Reserved
4 Interior
Delay 9 Secondary
Delay
Reserved
085 11 Reserved
5
Int. Follow
10
Sup. 24 Hr Silent
Reserved
LOCATION
PAGE
DESCRIPTION
ZONE ID
EVENT/EXT CODE
DEFAULT
086-087
12
Duress Communicator Code
"0" Disabled
088-089
12
Aux 1 Communicator Code
"0" Disabled
090-091
12
Aux 2 Communicator Code
"0" Disabled
092-093
12
Keypad Panic Communicator Code
"2 - 0"
094-095
12
Tamper Communicator Code
"0" Disabled
096-097
12
Download Complete Comm Code
"0" Disabled
098-099
12
Autotest Communicator Code
"0" Disabled
100-101
13
Failure To Communicate Report
"0" Disabled
102
13
Closing Communicator Code
Man Number
"0" Disabled
103
13
Opening Communicator Code
Man Number
"0" Disabled
104-105
13
Zone 1 Communicator Code
"1 - 0"
106-107
13
Zone 2 Communicator Code
"2 - 0"
108-109
13
Zone 3 Communicator Code
"3 - 0"
110-111
13
Zone 4 Communicator Code
"4 - 0"
112-113
13
Zone 5 Communicator Code
"5 - 0"
114-115
13
Zone 6 Communicator Code
"6 - 0"
116-119
14 Reserved
Reserved
120-121
14
Ac Power Loss Communicator Code
"0" Disabled