APPENDIX 1 - REPORTING IN SIA FORMAT
The 8600E has the ability to report SIA level 1 transmissions to either or both phone numbers. Each report in SIA consists
of an Event Code and a Zone or User ID. The Zone or User ID is programmed in the first digit of each report. When
programming the event code (the second digit) for zones 1-8 (locations 105, 107, 109, 111, 113, 115, 117 or 119),
programming a zero will cause the event code to follow the zone type for that zone. The event code for the zone type can
be overridden by programming a digit from the table below. Duress (location 87), AUX 1 (location 89), AUX 2 (location 91),
and keypad Panic (location 93) must be programmed from the table below:
Programmed Event Code
SIA Code
Description
1
FA
Fire Alarm
2 PA
Panic
alarm
3 BA
Burglary
Alarm
4
GA
Gas Alarm
5 KA
Heat
Alarm
6
WA
Water Alarm
7 QA
Emergency
Alarm
8
SA
Sprinkler Alarm
9 UA
Untyped
Alarm
10 HA
Holdup
Alarm
11 MA
Medical
Alarm
12
ZA Freeze
Alarm
13 TA
Tamper
Alarm
14
RP
Periodic Test
15
YF
System Fault
The following reports will send fixed event codes regardless of the number programmed in the event code location:
Event
SIA Code
Event Code Location
Keypad Tamper
TA
95
Download Complete
RS
97
Autotest
RP
99
Fail to Communicate
RT
101
Closing CL
102
Opening OP
103
AC Loss
AT
121
Low Battery
YT
123
Trouble
*T
124
Bypass
*B
125
Bypass
Restore
*U
125+126
Restore *R
126
Cancel OC
127
Maintenance
Open
OP
172
Maintenance
Close
CL
173
Exit Error
EE
210
Recent
Closing
CR
211
Auxiliary
3
UA
253
User on site
YY
254
*These will send the event code for the zone bypassed, restored, or in trouble.