Setting up the CM-MD64 for a MADI Network
The following section provides a guide on how to set up the Cadac CM-MD64.
Front Panel Dip Switch Settings
The table below shows how the unit can be configured via from Configuration DIP switch [3] on the front
panel:
DIP Switch
Mode
ON
OFF
DIP 1
MADI Channel / Stream 1
COAX RX
OPTICAL RX
DIP 2
MADI Channel / Stream 2
COAX RX
OPTICAL RX
DIP 3
Clock Speed
96 kHz
48 kHz
DIP 4
SYNC
EXTERNAL
INTERNAL
DIP 5
SYNC Source
WORD
CLOCK
MADI
Important Notes
•
DIP switches 6, 7, 8 are set to OFF
•
Definitions of EXTERNAL / INTERNAL operation above DO NOT relate to MegaCOMMS. The
CM-DM64 will always follow MegaCOMMS when connected to a Cadac digital console.
•
One MADI port Tx connection may not be routed to a Rx connection from the same port