![background image](http://html1.mh-extra.com/html/cadac/cm-md64/cm-md64_hardware-overview_4314833021.webp)
CM-MD64_24-05-2023_Iss-1.docx
Page. 21 / 31
NOTE
: Only RG6 video cable suitable for 3G HD-SDI (High-Definition Serial Digital Interface) should be
used for the Cadac MegaCOMMS connections. The cables should be terminated in BNC connectors of
the appropriate type, and total system cable run should not exceed 100m
(surface-to-stage rack or
stage rack to stage rack as a snake). A suitable cable: Kramer bulk Type BC-1X.
Cadac CM-J
series
CM-SR series stage rack
Coaxial Cable Run
≤100m
Coaxial Cable Run
Linking CM-MD64 and
CM-
SR ≤ 100m
CM-MD64
NOTE:
With the system setup above MegaCOMMS
PORT A
on the first stage rack MUST be connected to the console.
Cadac CM-J
series
CM-SR series stage rack
Cable Run ≤ 2 km
CM-MD64
System below using one CM-MD64 and CM-SR stage rack using coaxial cables only
System below using one CM-MD64 and CM-SR stage rack with the CM-SR using fibre optic cable
Coaxial Cable Run
Linking CM-SR and
CM-
MD64 ≤ 100m
NOTE:
With the system setup above MegaCOMMS
PORT A
on the first stage rack MUST be connected to the console.
Console and daisy chaining one CM-MD64 and one CM-SR stage rack