20
LOCATION
APPLICATION
UPFLOW
DOWNFLOW
HORIZONTAL
FURNACE
Ø
5.08 cm (2")
5.08 cm (2")
SUPPLY PLENUM WITHIN 6 ft. OF FURNACE
2.54 cm (1")
5.08 cm (2")
2.54 cm (1")
BACK
FURNACE
Ø
2.54 cm (1")
Ø
FURNACE OR PLENUM
5.08 cm (2")
5.08 cm (2")
5.08 cm (2")
HORIZONTAL WARM AIR DUCT WITHIN 6 ft. OF FURNACE
5.08 cm (2")
5.08 cm (2")
7.62 cm (3")
BOTTOM
FURNACE (COMBUSTIBLE FLOOR WITH THE SUB-BASE †)
Ø
* Ø
** Ø
HORIZONTALLY OR BELOW FLUE PIPE
10.16 cm (4")
10.16 cm (4")
10.16 cm (4")
VERTICALLY ABOVE FLUE PIPE
22.86 cm (9")
22.86 cm (9")
22.86 cm (9")
FRONT
FURNACE
20.32 cm (8")
20.32 cm (8")
60.96 cm (24")
SIDES
TOP
FLUE PIPE
Figure 12 : Model CVM Size 120
Table 11 : Minimum clearances to combustible materials
† When used with floor base model: *KLASB0601DET or **KLASB0701DET