2
TABLE OF CONTENTS
1.0
SAFETY REGULATIONS ---------------------------------------3
1.1
DANGER, WARNING AND CAUTION --------------------3
1.2
SAFETY INSTALLATION REQUIREMENTS ------------3
2.0
INSTALLATION ---------------------------------------------------3
2.1
GENERAL -------------------------------------------------------3
2.2
SAFE INSTALLATION REQUIREMENTS----------------4
2.3
SAFETY RULES -----------------------------------------------4
2.3.1
Detector
--------------------------------------------------4
2.3.2
Freezing temperatures and your building
----------4
2.4
LOCATION ------------------------------------------------------5
2.4.1
Air for combustion and ventilation
-------------------5
2.4.2
Duct recommendations
--------------------------------6
2.4.3
Venting instructions (chimney installation)
--------6
2.4.4
Draft Regulator
-----------------------------------------7
2.4.5
Blocked vent shut-off (BVSO) for chimney
venting
---------------------------------------------------7
2.4.6
Oil burner
------------------------------------------------8
2.4.7
Electrical system
---------------------------------------9
2.4.8
24V Wiring
--------------------------------------------- 10
2.4.9
Accessory installation
------------------------------- 10
2.4.10
Air filter
------------------------------------------------- 10
2.4.11
Air Conditioner (or Heat Pump)
-------------------- 11
2.4.12
Horizontal or downflow installation
---------------- 11
3.0
OPERATION ----------------------------------------------------- 11
3.1
SUPPLY AIR ADJUSTMENTS---------------------------- 11
3.2
OPERATIONAL CHECKLIST ----------------------------- 11
3.3
PURGING THE OIL LINE ---------------------------------- 12
3.4
COMBUSTION CHECK ------------------------------------ 12
3.5
SEQUENCE OF OPERATION ---------------------------- 13
3.5.1
Oil fired heating mode
------------------------------- 13
3.5.2
Cooling mode
----------------------------------------- 13
3.5.3
Continuous Blower Mode
--------------------------- 13
3.5.4
Heat Pump – Heating / Cooling Mode
------------ 13
3.5.5
Defrost Mode
------------------------------------------ 14
3.6
LIMIT CONTROL CHECK---------------------------------- 14
4.0
MAINTENANCE ------------------------------------------------- 14
4.1
HEAT EXCHANGER CLEANING ------------------------ 14
4.2
BLOWER REMOVAL---------------------------------------- 14
4.3
BLOCKED VENT SHUT OFF (BVSO) CLEANING ---- 14
5.0
FURNACE INFORMATION----------------------------------- 15
FIGURES
Figure 1 : Counterflow position, flue pipe protection .................. 5
Figure 2 : Wiring diagram,BVSO................................................ 7
Figure 3 : BVSO device wiring, upflow installation with vertical
exhaut ....................................................................... 8
Figure 4 : BVSO device wiring, upflow installation with vertical
exhaust ..................................................................... 9
Figure 5 : BVSO device wiring, upflow installation with horizontal
exhaust ..................................................................... 9
Figure 6: BVSO device wiring, horizontal installation with
horizontal exhaust..................................................... 9
Figure 7: BVSO device wiring, horizontal installation with vertical
exhaust ..................................................................... 9
Figure 8: BVSO device wiring, downflow installation.................. 9
Figure 9 : 24 VAC Oil Furnace Wiring with Air Conditioner ...... 10
Figure 10 : 24 VAC Oil Furnace Wiring with Heat Pump.......... 10
Figure 11 : Model CVM Size 105 ............................................. 19
Figure 12 : Model CVM Size 120 ............................................. 20
Figure 13 : Wiring diagram CVM.............................................. 21
Figure 14 : Parts list CVMAAR036105 ..................................... 22
Figure 15 : Parts list CVMAAR060120 ..................................... 24
TABLES
Table 1 : Minimum dimensions required in ventilation openings 5
Table 2 : Filter rack flange dimensions for return air duct ........ 11
Table 3 : Supply air adjustments, heating mode ...................... 11
Table 4 : Supply air adjustments, air conditioning mode .......... 11
Table 5 : CFM adjustments, all modes..................................... 12
Table 6 : Delay adjustments, heating mode ............................. 12
Table 7 : Technical Specifications ........................................... 16
Table 8 : Air Flow Data, Size 105............................................. 17
Table 9 : Air Flow Data, Size 120............................................. 18
Table 10 : Minimum clearances to combustible materials ........ 19
Table 11 : Minimum clearances to combustible materials ........ 20
Table 12 : Parts list CVMAAR036105 ...................................... 23
Table 13 : Parts list - CBMAAA060120 .................................... 25
Summary of Contents for CVMAAR036105
Page 21: ...21 Figure 13 Wiring diagram CVM ...
Page 22: ...22 Figure 14 Parts list CVMAAR036105 B50003 Rev D ...
Page 24: ...24 Figure 15 Parts list CVMAAR060120 B50004 Rev F ...
Page 48: ...23 Figure 13 Diagramme électrique CVM ...
Page 49: ...24 Figure 14 Liste de pièces CVMAAR036105 B50003 Rev D ...
Page 51: ...26 Figure 15 Liste de pièces CVMAAR060120 B50004 Rev F ...