Configuring the Trap Table
3-22
Trap Messages
Exit Service Affecting Condition
533
The situation that caused event 362 has ended.
Severity
Major (Level 2)
DLCI “n” Frm Relay PVC Disconnected
534
Self-explanatory.
Severity
Informational (Level 4)
DLCI “n” Received Bad Frame
535
Either the DLCI was not conÞgured or the frame was on an unavailable DLCI.
Severity
Minor (Level 3)
Action
ConÞgure the DLCI or resent the frame.
DLCI “n” No Response to STATUS ENQ
536
There was no response to a status enquiry from the DTE.
Severity
Minor (Level 3)
Action
Check the status of the DCE.
DLCI “n” Flow Control On
537
Flow control has been implemented on a frame relay port and data is queued.
Severity
Minor (Level 3)
DLCI “n” Frame Discarded—Flow Ctl
538
Self-explanatory.
Severity
Minor (Level 3)
Action
The frame must be resent.
DLCI “n” Line does not exist
539
Self-explanatory.
Severity
Minor (Level 3)
Action
Check the conÞguration records for the node, LP and port.
DLCI “n” Not Configured
540
Self-explanatory.
Severity
Minor (Level 3)
Action
ConÞgure the DLCI in the portÕs database record.
Summary of Contents for SPECTRUM FRX6000
Page 2: ......
Page 112: ...Frame Relay Status and Configuration 5 24 Viewing Frame Relay Status ...
Page 124: ...X 25 Status and Configuration 6 12 Viewing X 25 Status ...
Page 168: ...BSC Interactive Configuration 8 12 Configuring BSCI Devices ...
Page 224: ...SmartSwitch 1800 Voice Configuration 12 20 Viewing Voice Statistics ...