4-28 SmartSwitch 9A100 User Guide
Upgrading and Changing Software
Switch Administration
............................................................................
............................................................................
............................................................................
.......................................
Validity checks of POST software Downloaded file...
All Validity checks OK
Programming downloaded image into POST Software section, please wait...
New POST Software programmed successfully
=>
9.
Check whether the diagnostic download is successful by entering the
go P
command. This forces
the SmartSwitch 9A100 to run POST before starting the switch software.
4.7.5
Upgrading Switch Operating Software
Note
SmartSwitch 9A100 operating software can also be updated using the switch
console
update firmware
command. See Section 4.7.6, “Using the Update
Firmware Command.”
1.
Set up the TFTP/Bootp server software on a workstation.
2.
Connect both the TFTP/Bootp server and the SmartSwitch 9A100 to your Ethernet network. Make
sure that the TFTP/Bootp server can be reached by the SmartSwitch 9A100 Ethernet interface.
3.
Connect a dumb terminal (or PC running terminal emulation software) to the SmartSwitch 9A100
Terminal port.
4.
Copy the SmartSwitch 9A100 switch operating software image into the appropriate location on the
TFTP/Bootp server. (In this example, the software is located at c:\tftpboot\images\server.ima.)
5.
Set up the TFTP/Bootp server tables (or equivalent file) with:
-
SmartSwitch 9A100 MAC address
-
IP address of the SmartSwitch 9A100 Ethernet interface
-
path to the POST file on the TFTP/Bootp server
6.
From the terminal connection, enter the
reboot
command.
7.
When the following message appears,
“Press any key to exit to boot load prompt.”
stop the countdown by pressing any key. The boot load prompt (=>) appears on the terminal screen.
8.
Enter the
df s
command. The SmartSwitch 9A100 contacts the TFTP/Bootp server and downloads
the switch operating software into flash RAM.
=>df s
You've requested a Switch Software download
Are you sure?(Y/N)y
Initializing ethernet...
Starting Bootp...
Boot file: c:\tftpboot\images\server.ima
Using TFTP to get bootfile "c:\tftpboot\images\server.ima" .
...........................................................................
...........................................................................
...........................................................................
...........................................................................
Summary of Contents for SmartSwitch 9A100
Page 12: ...xii SmartSwitch 9A100 User Guide TABLE OF CONTENTS...
Page 14: ...xiv SmartSwitch 9A100 User Guide List of Figures...
Page 16: ...xvi SmartSwitch 9A100 User Guide List of Tables...
Page 18: ...1 2 SmartSwitch 9A100 User Guide Introduction...
Page 34: ...2 16 SmartSwitch 9A100 User Guide SmartSwitch ATM Administrator Switch Installation and Setup...
Page 42: ...3 8 SmartSwitch 9A100 User Guide F amV m h d F 2 6 3 F 1 m 2...
Page 80: ...5 6 SmartSwitch 9A100 User Guide Troubleshooting Congestion Troubleshooting...
Page 86: ...A 6 SmartSwitch 9A100 User Guide Technical Specifications Specifications...