vi SmartSwitch 9A100 User Guide
FIBER OPTIC PROTECTIVE CAPS
%
"¤›apm
READ BEFORE REMOVING FIBER OPTIC PROTECTIVE CAPS.
Cable assemblies and MMF/SMF ports are shipped with protective caps to prevent contamination. To avoid
contamination, replace port caps on all fiber optic devices when not in use.
Cable assemblies and MMF/SMF ports that become contaminated may experience signal loss or difficulty inserting
and removing cable assemblies from MMF/SMF ports.
Contamination can be removed from cable assemblies by
U
Blowing surfaces with canned duster (Chemtronics p/n ES1270 or equivalent).
U
Using a fiber port cleaning swab (Alcoa Fujikura LTS p/n ACT-01 or equivalent) saturated with
optical-grade isopropyl alcohol, gently wipe the end surface of ferrules first; then wipe down the
sides of both ferrules.
U
Blow ferrule surfaces dry with canned duster.
Contamination can be removed from MMF/SMF ports by
U
Using the extension tube supplied with canned duster, blow into the optical port, being careful not
to allow the extension tube to touch the bottom of the optical port.
U
Reconnect cable and check for proper mating. If problems remain, gently wipe out optical port with
a DRY fiber port cleaning swab and repeat step 1.
%
"¤›apm
To avoid contamination, replace port caps on all fiber optic devices when not in
use.
Summary of Contents for SmartSwitch 9A100
Page 12: ...xii SmartSwitch 9A100 User Guide TABLE OF CONTENTS...
Page 14: ...xiv SmartSwitch 9A100 User Guide List of Figures...
Page 16: ...xvi SmartSwitch 9A100 User Guide List of Tables...
Page 18: ...1 2 SmartSwitch 9A100 User Guide Introduction...
Page 34: ...2 16 SmartSwitch 9A100 User Guide SmartSwitch ATM Administrator Switch Installation and Setup...
Page 42: ...3 8 SmartSwitch 9A100 User Guide F amV m h d F 2 6 3 F 1 m 2...
Page 80: ...5 6 SmartSwitch 9A100 User Guide Troubleshooting Congestion Troubleshooting...
Page 86: ...A 6 SmartSwitch 9A100 User Guide Technical Specifications Specifications...