Power-up and Test
CSMIM2 Installation Guide
2-9
3.
Verify the CSMIM2/MODMIM hardware configuration.
At the monitor prompt on the console, type config and press the
Return key. The following is a typical
MODMIM-4 configuration display:
monitor::
config
Revision/Configuration Information
ROM Software Rev #0800
Board ID 42
Ethernet Address 00-80-2D-00-B8-3C
Memory Size:2 Meg
Flash Size: N/A
Flash ID: N/A
EEPROM Size: 65504
Total Number of Ports: 20
ASYNC Config
Number of Ports: 16
Max Port Speed: 115.2 Kbps
MODEM Config
Number of Ports: 4
Port # 17 18 19 20
ID 1445 1445 1445 1445
Status OK OK OK OK
To record the CSMIM2’s Ethernet address for future reference: at the
monitor prompt, type addr -d and press the Return key. The display
looks like this:
monitor::
addr -d
Ethernet address (hex): 00-80-2D-00-B8-3C
Internet address: <invalid or uninitialized>
Subnet mask: <invalid or uninitialized>
Preferred load host address: <any host>
Broadcast address: 0.0.0.0
Preferred dump address: 0.0.0.0
Type of IP packet encapsulation: <ethernet>
Load broadcast: N
NOTE
You are prompted for the gateway address only if the internet
address differs from the preferred load host address based on
the subnet mask. If these addresses are the same, the
CSMIM2 assumes there is no gateway.