background image

 

4-1

 

Chapter 4

 

Specifications

 

Safety

 

The 9C214-3 power supply, when properly installed on the SmartSwitch 9000 
chassis, complies with the following safety specifications and standards:

UL 1950

CSA C22.2 No. 950 

EN 60950

IEC 950

EMI Requirements of FCC Part 15 Class A

EN 55022 Class A

VCCI Class I

EMC requirements of

EN 50082-1
IEC 801-2 ESD
IEC 801-3 Radiated susceptibility
IEC 801-4 EFT 

 

Service

 

The 9C214-3 power supply is designed with the following service capability:

 

MTBF (MIL-STD-217): >200,000 hours projected

MTTR: <.50 

hour

It is the responsibility of the person who sells the system to which the modules 
will be a part to ensure that the total system meets allowed limits of conducted 
and radiated emissions.

!

CAUTION

Summary of Contents for 9C214-3

Page 1: ...9032529 01 SmartSwitch 9000 9C214 3 AC Power Supply Installation Guide...

Page 2: ......

Page 3: ...EVER INCLUDING BUT NOT LIMITED TO LOST PROFITS ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT EVEN IF CABLETRON SYSTEMS HAS BEEN ADVISED OF KNOWN OR SHOULD HAVE KNOWN THE...

Page 4: ...in which case the user will be required to correct the interference at his own expense WARNING Changes or modifications made to this device which are not expressly approved by the party responsible fo...

Page 5: ...Equipment for use in a Commercial or Light Industrial Environment We the undersigned hereby declare under our sole responsibility that the equipment packaged with this notice conforms to the above di...

Page 6: ...Notice iv...

Page 7: ...9000 Chassis 2 1 Powering Up the 9C214 3 Power Supply 2 3 Chapter 3 9C214 3 Power Supply Operation Operating Functions 3 1 System Diagnostic Controller 3 2 Internal Temperature Sensor 3 2 Power Suppl...

Page 8: ...Contents vi...

Page 9: ...or unpacking installing and powering up the 9C214 3 power supply Chapter 3 9C214 3 Power Supply Operation contains detailed information regarding the power supply operation Chapter 4 Specifications pr...

Page 10: ...igure 1 1 The 9C214 3 Power Supply 207 264v 12A 50 60 Hz 9C214 3 100 50 0 Load POWER SUPPLY MODULE STATUS P W R S N B Status LED Power Supply SMB Status LED Power Supply Level Indicator LED Power Swit...

Page 11: ...214 3 power supply This circuit protects the power supply from overheating if a thermal overload occurs Automatic recovery takes place after the thermal overload condition is corrected Load Sharing Ea...

Page 12: ...from 40 60 volts DC This capability allows the SmartSwitch 9000 to operate from typical AC power and to charge batteries in a battery backup unit or operate on DC power such as found in a central off...

Page 13: ...Cabletron Systems products in the network A description of your network environment layout cable type etc Network load and frame size at the time of trouble if known The device history i e have you re...

Page 14: ...Introduction 1 6...

Page 15: ...e the shipping box and packing materials in the event the power supply must be reshipped 2 Remove the power supply from the protective plastic bag Save the bag in the event the power supply must be re...

Page 16: ...pushing the power supply in until its frame touches the surface of the SmartSwitch 9000 chassis Do not force the power supply in place If significant resistance is encountered before the frame is flu...

Page 17: ...AC receptacle Turn on the power supply using the switch located near the power socket 3 The power supply uses a soft start feature and does a pre power diagnostic check Outputs become enabled within 5...

Page 18: ...Installing the 9C214 3 Power Supply 2 4...

Page 19: ...ply converts the 207 264 VAC to three different DC outputs for internal use by the system Each of these outputs is described below 56 volts supplied to the 48 volt DC System Power Bus for use througho...

Page 20: ...a built in temperature sensor for monitoring its own internal temperature The results of the monitoring are available to the network manager via LCD as well as local and remote management Power Supply...

Page 21: ...nd 3 3 volt outputs are within established tolerances Yellow Crippled Not fully operational 56 volt output is not within established tolerances due to lack of AC input Red Fault One of the system powe...

Page 22: ...cription 1 5 Green 10 50 of power load being used No action necessary 6 9 Green 60 90 of power load being used No parallel power supply operational No action necessary 6 9 Yellow 60 90 of power load b...

Page 23: ...ss A EN 55022 Class A VCCI Class I EMC requirements of EN 50082 1 IEC 801 2 ESD IEC 801 3 Radiated susceptibility IEC 801 4 EFT Service The 9C214 3 power supply is designed with the following service...

Page 24: ...drawn through the chassis Universal AC Input Each 9C214 3 power supply accepts input voltage ranging from 207 264 volts at 50 60 Hz Input Voltage Each 9C214 3 power supply will draw the following cur...

Page 25: ...4 3 Specifications Output Voltage Each 9C214 3 power supply is capable of generating the following output voltages 56 0 volts 35A 3 3 volts 17A 5 1 volts 18A...

Page 26: ...Specifications 4 4...