Setting the Mode Switches
6E123-50 and 6E133-49 User’s Guide
C-3
•
After changing the position of switch 6 and restarting the module, the
6E123-50 and 6E133-49 request a new image download until they
either receive a new image or the RESET button on the front panel is
pressed. When the RESET button is pressed, the 6E123-50 and
6E133-49 continue trying to contact a BootP server, but will time out
in approximately one minute. If the module times out, the image is
downloaded from its FLASH memory.
•
Switch 7 – Clear NVRAM. Changing the position of this switch resets
NVRAM on either the next power up or the next operation of the front
panel RESET switch. ALL user entered parameters, such as IP
addresses, subnet masks, SNMP traps, and bridging functions are
restored to their factory default settings.
•
Switch 8 – Reset Password/Community Strings. Changing the position
of this switch clears only the user-entered passwords stored in
NVRAM, and restores the default passwords. Once the 6E132-25 or
6E122-26 is reset, the passwords can either be reentered or the default
passwords (Public and ENTER) may be used.
NOTE
Do not change the position of switch 8 unless it is necessary to
reset the module super-user configured passwords to their
factory default settings.