Appendix B: FE-100TX, FE-100FX, and FE-100F3 Specifications
B-2
2H23-50R/2H33-37R User’s Guide
B.2
FE-100FX
The FE-100FX shown in
Figure B-2
uses an SC style connector that
supports multimode fiber optic cabling. Specifications for the FE-100FX
are listed in
Table B-1
, below.
Figure B-2
FE-100FX
Table B-1
Transmitter Power
Cable Type
Worst Case Budget
Typical Budget
50/125 µm fiber optic
6.0 dB
9.0 dB
62.5/125 µm fiber optic
9.0 dB
12.0 dB
100/140 µm fiber optic
15.0 dB
18.0 dB
NOTE
The transmitter power levels and receive sensitivity levels listed
are peak power levels after optical overshoot. A peak power
meter must be used to correctly compare the values given
above to those measured on any particular port. If power levels
are being measured with an average power meter, add 3 dB to
the measurement to compare the measured values to the
values listed above.
6
5
2286-40
FE-100FX
Summary of Contents for 2H23-50R
Page 2: ......
Page 8: ...Notice vi 2H23 50R 2H33 37R User s Guide...
Page 24: ...Chapter 1 Introduction 1 12 2H23 50R 2H33 37R User s Guide...
Page 42: ...Chapter 3 Installation 3 16 2H23 50R 2H33 37R User s Guide...
Page 158: ...Chapter 5 Local Management 5 108 2H23 50R 2H33 37R User s Guide...
Page 162: ...Appendix A Specifications A 4 2H23 50R 2H33 37R User s Guide...
Page 166: ...Appendix B FE 100TX FE 100FX and FE 100F3 Specifications B 4 2H23 50R 2H33 37R User s Guide...
Page 182: ...Index Index 6 2H23 50R 2H33 37R User s Guide...